Appendix B: Sensor Tables
Intel
®
Server Board S5500BC TPS
Intel order number: E42249-003
Revision 1.0
90
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert /
De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
Front Panel Temperature
(Front Panel Temp)
21h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R,
T A X
IOH Thermal Margin
(IOH Therm Margin)
22h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R,
T A –
Processor 1 Memory
Thermal Margin
(Mem P1 Thrm Mrgn)
23h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R,
T A –
Processor 2 Memory
Thermal Margin
(Mem P2 Thrm Mrgn)
24h
Dual
processor
only
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R,
T A –
Fan Tachometer Sensors
(Chassis specific
sensor names)
30h–39h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc = Degraded
c = Non-fatal
2
As and
De
Analog R,
T M
–
Fan Present Sensors
(Fan x Present)
40h–45h
Chassis-
specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As and
De
-
Triggered
Offset
Auto
–
00 - Fully
redundant
OK
As and
De
–
01 - Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded
Fan Redundancy
1
(Fan Redundancy)
46h
Chassis-
specific
Fan
04h
Generic
0Bh
03 - Non-
redundant:
Sufficient
resources.
Transition from
redundant
Degraded
Trig
Offset
A