Intel AMT WebGUI
The Intel® AMT WebGUI is a Web browser-based interface for limited remote computer management. The WebGUI is often
used as a test to determine if Intel AMT setup and configuration was performed properly on a computer. A successful remote
connection between a remote computer and the host computer running the WebGUI indicates proper Intel AMT setup and
configuration on the remote computer.
The Intel AMT WebGUI is accessible from any Web browser, such as the Internet Explorer® or Netscape® applications.
Limited remote computer management includes:
Hardware inventory
Event logging
Remote computer reset
Changing of network settings
Addition of new users
WebGUI support is enabled by default for SMB setup and configured computers. WebGUI support for Enterprise setup and
configured computers is determined by the setup and configuration server. Information on using the WebGUI interface is
available on the
Intel AMT website
.
An older version of the WebGUI interface is available at
Intel AMT Small Business Administrator's Guide
under
Using the Web
Browser Interface
on page 4.
Follow the steps below to connect to the Intel AMT WebGUI on a computer that has been configured and set up :
1. Turn on an Intel AMT capable computer that has completed Intel AMT setup and configuration.
2. Launch a Web browser from a separate computer, such as a management computer on the same subnet as the Intel
AMT computer.
3. Connect to the IP address specified in the MEBx and port of the Intel AMT capable computer. (example:
http://ip_address:16992
or
http://192.168.2.1:16992
)
By default, the port is 16992. Use port 16993 and https:// to connect to the Intel AMT WebGUI on a computer
that has been configured and set up in the Enterprise mode.
If DHCP is used, then use the fully qualified domain name (FQDN) for the ME. The FQDN is the combination of
the host name and domain. (example:
http://host_name:16992
or
http://system1:16992
)
The management computer makes a TCP connection to the Intel AMT capable computer and accesses the top level
Intel AMT-embedded Web page within the Management Engine of the Intel AMT capable computer.
4. Type the username and password. The default username is
admin
and the password is what was set during Intel AMT
setup in the MEBx.
5. Review the computer information and make any necessary changes.
You can change the MEBx password for the remote computer in the WebGUI. Changing the password in the WebGUI or a
remote console results in two passwords. The new password, known as the remote MEBx password, only works remotely with
the WebGUI or remote console. The local MEBx password used to locally access the MEBx is not changed. You have to
remember both the local and remote MEBx passwords to access the computer MEBx locally and remotely. When the MEBx
password is initially set in Intel AMT setup, the password serves as both the local and remote password. If the remote
password is changed, then the passwords are out of sync.
6. Select
Exit
.
Back to Contents Page
Содержание Active Management Technology v5.0
Страница 32: ...4 Click the to expand the Intel AMT Getting Started section ...
Страница 33: ...5 Click the to expand the Section 1 Provisioning section ...
Страница 34: ...6 Click the to expand the Basic Provisioning without TLS section ...
Страница 37: ...The IP address for the ProvisionServer and Intel SCS are now visible ...
Страница 38: ...9 Select Step 2 Discovery Capabilities ...
Страница 39: ...10 Verify that the setting is Enabled If Disabled click the check box next to Disabled and click Apply ...
Страница 40: ...11 Select Step 3 View Intel AMT Capable Computers ...
Страница 41: ...Any Intel AMT capable computers on the network are visible in this list ...
Страница 42: ...12 Select Step 4 Create Profile ...
Страница 43: ...13 Click the plus symbol to add a new profile ...
Страница 47: ...15 Select the icon with the arrow pointing out to Export Security Keys to USB Key ...
Страница 48: ...16 Select the Generate keys before export radio button ...
Страница 55: ...27 Select Step 7 Monitor Provisioning Process ...
Страница 57: ...28 Select Step 8 Monitor Profile Assignments ...
Страница 60: ...Back to Contents Page ...
Страница 63: ...6 Press y when the following message appears System resets after configuration change Continue Y N ...
Страница 66: ...9 Select Intel ME Features Control and then press Enter ...
Страница 68: ...10 Select Return to Previous Menu and then press Enter ...
Страница 69: ...11 Select Intel ME Power Control and then press Enter ...
Страница 70: ...Intel ME ON in Host Sleep States is the next option The default setting is Mobile ON in S0 ...
Страница 71: ...12 Select Return to Previous Menu and then press Enter ...
Страница 72: ...13 Select Return to Previous Menu and then press Enter ...
Страница 75: ...6 Select TCP IP and then press Enter 7 Press n when the following message appears DHCP Enable Disable DHCP Y N ...
Страница 76: ...8 Type the domain name into the Domain name field ...
Страница 78: ...11 Select Setup and Configuration from the menu and then press Enter ...
Страница 81: ...14 Select Provisioning Server from the menu and then press Enter ...
Страница 84: ...17 Select Provisioning Server FQDN from the menu and then press Enter ...
Страница 85: ...18 Type the fully qualified domain name FQDN for the provisioning server and press Enter ...
Страница 86: ...19 Select TLS PSK from the menu and then press Enter ...
Страница 89: ...22 Select TLS PKI from the menu and then press Enter ...
Страница 93: ...26 Select Return to Previous Menu and press Enter ...
Страница 94: ...27 Select Return to Previous Menu and then press Enter This returns you to the Intel AMT Configuration menu ...
Страница 96: ...28 Select SOL IDE R and then press Enter ...
Страница 97: ...29 Press y when the following message appears Caution System resets after configuration changes Continue Y N ...
Страница 99: ...For Serial Over LAN SOL IDE R select Enabled and then press Enter ...
Страница 100: ...For IDE Redirection select Enabled and then press Enter ...
Страница 101: ...Password Policy is the next option The default setting is Default Password Only ...
Страница 102: ...Secure Firmware Update is the next option The default setting is Enabled ...
Страница 103: ...Skip Set PRTC ...
Страница 105: ...30 Select Return to Previous Menu and then press Enter ...
Страница 106: ...31 Select Exit and then press Enter ...
Страница 107: ...32 Press y when the following message appears Are you sure you want to exit Y N ...
Страница 111: ...7 Press y when the following message appears System resets after configuration change Continue Y N ...
Страница 114: ...10 Select Intel ME Features Control and then press Enter ...
Страница 116: ...11 Select Return to Previous Menu and then press Enter ...
Страница 117: ...12 Select Intel ME Power Control and then press Enter ...
Страница 118: ...Intel ME ON in Host Sleep States is the next option The default setting is Mobile ON in S0 ...
Страница 119: ...13 Select Return to Previous Menu and then press Enter ...
Страница 120: ...14 Select Return to Previous Menu and then press Enter ...
Страница 123: ...6 Select TCP IP and then press Enter 7 Press n when the following message appears DHCP Enable Disable DHCP Y N ...
Страница 124: ...8 Type the domain name into the field ...
Страница 127: ...13 Press y when The following message appears Caution System resets after configuration changes Continue Y N ...
Страница 129: ...15 For Serial Over LAN select Enabled and then press Enter ...
Страница 130: ...16 For IDE Redirection select Enabled and then press Enter ...
Страница 131: ...17 For Password Policy select Enabled and then press Enter ...
Страница 132: ...Secure Firmware Update is the next option The default setting is Enabled ...
Страница 133: ...18 Skip Set PRTC ...
Страница 135: ...19 Select Return to Previous Menu and then press Enter ...
Страница 136: ...20 Select Exit and then press Enter ...
Страница 137: ...21 Press y when the following message appears Are you sure you want to exit Y N ...