Integrated Visual Data Technology Inc. ED3-AT SkidWeigh Plus Series Скачать руководство пользователя страница 4

!

                                 

Electrical connections 

All SkidWeigh Plus systems operate from 12 to 55 VDC.                                                                                                          

                                                                                                                           

Orange Wire (+) Ignition switch                                                                                                                                    

- Brown Wire (-) Battery negative                                                                                                                                  
- Red Wire, connect to RED wire of the pressure transducer cable                                                                                                          
- Black Wire, connect to BLACK wire of the pressure transducer cable                                                                                                               
- White Wire, connect to WHITE wire of the pressure transducer cable

                                                                           

Power short circuit protection  

                                                                                                           

All SkidWeigh systems are internally short circuit protected with resettable fuse. There is no need to install external inline 
fuse in orange wire connected to the ignition switch. 

Note:

 All data is recorded in excel file. 

                                                                                                                                                                            

Verification of the electrical connections done properly

                                                                                        

                                                                                                                                                                  

- Turn on vehicle power switch                                                                                                                                                
- Lower forks to the ground                                                                                                                                                                                                                                                                                                                                                                                                                                              
- Digital LCD display will be activated, showing software version and serial number                                                            
- Digital LCD display will show current date and time                                                                                                                                                                                                                                                                                                                                                 

If the above test is valid than the system electrical connections are done right.      

LCD Display

Aug 28, 2010

12:20:23

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7 

www.skidweigh.com

   

Bulgin USB Assembly

Содержание ED3-AT SkidWeigh Plus Series

Страница 1: ...Calibration Manual ED3 ED4 AT SkidWeigh Plus Series Lift Truck Onboard Check Weighing ED3 ED4 AT V1 30 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www...

Страница 2: ...an or end user electro and hydraulic technical installer Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper...

Страница 3: ...e transducer the hydraulic lift circuit must be pressure free Pressure transducer has 1 4 18 NPT male thread Use thread seal to ensure tight fit Selecting the mounting location for digital indicator N...

Страница 4: ...e fuse There is no need to install external inline fuse in orange wire connected to the ignition switch Note All data is recorded in excel file Verification of the electrical connections done properly...

Страница 5: ...LCD Display Special Functions Button Bluetooth Icon Keypad Enter key Toggle Arrows Keys in set up menu Print key FUNCTION MODE KEY F 9 ADMINISTRATIVE MENU Password protected F 0 OPERATOR MENU Bluetoot...

Страница 6: ...to memory stick Note Data collected will depend on the hardware software configuration ED3 ED4 UT10 to UT60 series To enter into the Administration Menu press F key and than press 9 key Input passwor...

Страница 7: ...tion and programming hub For the applications without Base Station use SET CLOCK MANUAL instructions To set clock date Follow the LCD instructions and press Enter key to confirm LCD Display MENU Passw...

Страница 8: ...ey to confirm new date time set up Set vehicle ID Maximum input number for vehicle ID is 3 digits LCD Display Aug 28 2010 12 20 23 LCD Display KEY to SCROLL F KEY TO EXIT LCD Display SET VEHICLE ID EN...

Страница 9: ...u to erase the SDRAM all files contained on the UTX SkidWeigh Plus Make selection Y or N and press Enter key to confirm selection and the system will automatically bring you back to the main screen in...

Страница 10: ...ter or move vehicle After few seconds system zero weight value will be calibrated and stored LCD will show Lower the empty forks to the ground The LCD display will prompt you to input known calibratio...

Страница 11: ...display will show date time System check weighing function calibration is completed System is ready to be used Overload Warning Function Optional As soon forks are lowered the LCD display will show T...

Страница 12: ...iod 8 hours End use programable 8 or 12 hours IDLING automatic unidentify true idling events within utilization factor Up to 5 valid downtime reasons applicable for material handling operation DEFAULT...

Страница 13: ...Oakville Ontario Canada L6L 0A7 www skidweigh com Loaded forks must be lowered to the ground LCD display must show date time Lift the load approximately 2 off the ground Do not use tilt side shift or...