Weighing scale function calibration
Make sure that forks are on the ground and LCD display is showing time and date.
To enter into the
Administration Menu
, press
F
key
and than press
9
key. Input password
521
.
Use left and right arrow keys to scroll for CALIBRATION 1 functions to calibrate weighing scale function.
Lift empty forks just above the ground. Do not manipulate the tilt, side shifter or move vehicle. After few
seconds system zero weight value will be calibrated and stored. LCD will show.
Lower the empty forks to the ground. The LCD display will prompt you to input known calibration load
weight. (In our example the known load weight is 2000)
LCD Display
Aug 28, 2010
12:20:23
LCD Display
MENU
Password = ___
LCD Display
CALIBRATION 1
LIFT EMPTY FORKS
LCD Display
CALIBRATION 1
LOWER FORKS
LCD Display
CALIBRATION 1
WEIGHT _
LCD Display
CALIBRATION 1
WEIGHT = 2000
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7