Integrated Visual Data Technology Inc. ED3-AT SkidWeigh Plus Series Скачать руководство пользователя страница 10

!

                                 

Weighing scale function calibration

 

   

                                                                     

 

Make sure that forks are on the ground and LCD display is showing time and date.

To enter into the 

Administration Menu

, press

 F

 key

 

and than press 

9

 key. Input password

 521

.

   

Use left and right arrow keys to scroll for CALIBRATION 1 functions to calibrate weighing scale function.    

 

Lift empty forks just above the ground. Do not manipulate the tilt, side shifter or move vehicle. After few 
seconds system zero weight value will be calibrated and stored. LCD will show.  

Lower the empty forks to the ground. The LCD display will prompt you to input known calibration load 
weight.  (In our example the known load weight is 2000)

  

LCD Display

Aug 28, 2010

12:20:23

LCD Display

MENU

Password = ___

LCD Display

CALIBRATION 1

LIFT EMPTY FORKS

LCD Display

CALIBRATION 1

LOWER FORKS

LCD Display

CALIBRATION 1

WEIGHT _

LCD Display

CALIBRATION 1

WEIGHT = 2000

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7 

www.skidweigh.com

   

Содержание ED3-AT SkidWeigh Plus Series

Страница 1: ...Calibration Manual ED3 ED4 AT SkidWeigh Plus Series Lift Truck Onboard Check Weighing ED3 ED4 AT V1 30 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www...

Страница 2: ...an or end user electro and hydraulic technical installer Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper...

Страница 3: ...e transducer the hydraulic lift circuit must be pressure free Pressure transducer has 1 4 18 NPT male thread Use thread seal to ensure tight fit Selecting the mounting location for digital indicator N...

Страница 4: ...e fuse There is no need to install external inline fuse in orange wire connected to the ignition switch Note All data is recorded in excel file Verification of the electrical connections done properly...

Страница 5: ...LCD Display Special Functions Button Bluetooth Icon Keypad Enter key Toggle Arrows Keys in set up menu Print key FUNCTION MODE KEY F 9 ADMINISTRATIVE MENU Password protected F 0 OPERATOR MENU Bluetoot...

Страница 6: ...to memory stick Note Data collected will depend on the hardware software configuration ED3 ED4 UT10 to UT60 series To enter into the Administration Menu press F key and than press 9 key Input passwor...

Страница 7: ...tion and programming hub For the applications without Base Station use SET CLOCK MANUAL instructions To set clock date Follow the LCD instructions and press Enter key to confirm LCD Display MENU Passw...

Страница 8: ...ey to confirm new date time set up Set vehicle ID Maximum input number for vehicle ID is 3 digits LCD Display Aug 28 2010 12 20 23 LCD Display KEY to SCROLL F KEY TO EXIT LCD Display SET VEHICLE ID EN...

Страница 9: ...u to erase the SDRAM all files contained on the UTX SkidWeigh Plus Make selection Y or N and press Enter key to confirm selection and the system will automatically bring you back to the main screen in...

Страница 10: ...ter or move vehicle After few seconds system zero weight value will be calibrated and stored LCD will show Lower the empty forks to the ground The LCD display will prompt you to input known calibratio...

Страница 11: ...display will show date time System check weighing function calibration is completed System is ready to be used Overload Warning Function Optional As soon forks are lowered the LCD display will show T...

Страница 12: ...iod 8 hours End use programable 8 or 12 hours IDLING automatic unidentify true idling events within utilization factor Up to 5 valid downtime reasons applicable for material handling operation DEFAULT...

Страница 13: ...Oakville Ontario Canada L6L 0A7 www skidweigh com Loaded forks must be lowered to the ground LCD display must show date time Lift the load approximately 2 off the ground Do not use tilt side shift or...

Отзывы: