Operation
The
ED3/ED4-AT SkidWeigh Plus
operation is based on the hydraulic pressure transducer mounted in the vehicle
lifting circuit
Pressure transducer installation
The pressure transducer must be installed in the lifting hydraulic line
between the
lift control valve and lift cylinder(s).
Mount a T-piece in lifting hydraulic line.
Pressure transducer installation precautions
Before installation of the pressure transducer the hydraulic lift circuit must be
pressure free.
Pressure transducer has 1/4”-18 NPT male thread. Use thread seal to ensure tight fit.
Selecting the mounting location for digital indicator
Note:
Use the mounting bracket with the anti vibration mount and fasten digital
indicator on the vehicle dashboard. There are many examples of mounting
locations that will depend on the vehicle model. However, additional mounting
items such as a flat brackets may be needed to help secure digital indicator.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7