General Installation Guide 

This

 ED3/ED4-AT SkidWeigh Plus V1.30 Series 

guide describes how to install, calibrate, test and use your material 

handling vehicle onboard check weighing system. Following the instructions in the

 ADMINISTRATIVE MENU

 guide will 

enable you to get the weighing scale calibrated and the system up and running. In the event that you require additional 
assistance, please contact customer support via e-mail at 

[email protected]

 , visit 

www.skidweigh.com

 or contact 

us at the address or contact number below: 

Integrated Visual Data Technology Inc.       

                                                                                                                    

3439 Whilabout Terrace, Oakville, ON, Canada, L6L 0A7                                                                                            
Phone: 905-469-0985 

Safety 

Always disconnect the vehicle battery while installing SkidWeigh system or any other electronic product.                   
Make sure that unit, pressure transducer and any other associated cables are securely mounted and do not impede any 
of the vehicle’s controls. Use care when routing the components cables. Route the cables where they will be protected. 
Use commonly accepted install practices for after market industrial vehicle electronic devices.                                      
The installation of the SkidWeigh systems should only be performed by an acknowledged lift truck dealer technician or 
end user electro and hydraulic technical installer.                                                                                                                                                                          
Here are two acceptable methods of making a wire connections:                                                                                            
* Soldering your connections (recommended)                                                                                                                     
* Crimp connectors ( with the use of the proper crimping tool)                                                                               
Regardless of the method you choose, ensure that the connection is mechanically sound and properly insulated. Use 
high quality electrical tape and shrink tubing where necessary. This product is connected directly to the vehicle’s ignition 
switch, 12 to 55 VDC. There is no on-off switch on the unit. 

Electro-Magnetic Compatibility 

CE conformity to EC directive 89/336 (EMC) by application of harmonized standards: Interference stability EN 61000-6-2 
and EN 61326-1 interference emit EN 61000-6-3, EN 61326-1 for the pressure transducer. 

ED3/ED4-AT SkidWeigh Plus Series 

Our policy is one of continuous improvement and the information in this document is subject to change without notice. 
The software version is displayed on the LCD display once the power is turned on to the system. 

Overview of components 

The standard ED3/ED4-AT SkidWeigh Plus system consist of two main components:                                                                        
* Digital indicator, wiring harness, mounting bracket and anti-vibration mount 

 

                                                                                                                                                                       

* Hydraulic pressure transducer with 3 wires cable                                                                                                             
* Installation & calibration manual and operator usage instruction                                                                                                                              

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7 

www.skidweigh.com

   

Содержание ED3-AT SkidWeigh Plus Series

Страница 1: ...Calibration Manual ED3 ED4 AT SkidWeigh Plus Series Lift Truck Onboard Check Weighing ED3 ED4 AT V1 30 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www...

Страница 2: ...an or end user electro and hydraulic technical installer Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper...

Страница 3: ...e transducer the hydraulic lift circuit must be pressure free Pressure transducer has 1 4 18 NPT male thread Use thread seal to ensure tight fit Selecting the mounting location for digital indicator N...

Страница 4: ...e fuse There is no need to install external inline fuse in orange wire connected to the ignition switch Note All data is recorded in excel file Verification of the electrical connections done properly...

Страница 5: ...LCD Display Special Functions Button Bluetooth Icon Keypad Enter key Toggle Arrows Keys in set up menu Print key FUNCTION MODE KEY F 9 ADMINISTRATIVE MENU Password protected F 0 OPERATOR MENU Bluetoot...

Страница 6: ...to memory stick Note Data collected will depend on the hardware software configuration ED3 ED4 UT10 to UT60 series To enter into the Administration Menu press F key and than press 9 key Input passwor...

Страница 7: ...tion and programming hub For the applications without Base Station use SET CLOCK MANUAL instructions To set clock date Follow the LCD instructions and press Enter key to confirm LCD Display MENU Passw...

Страница 8: ...ey to confirm new date time set up Set vehicle ID Maximum input number for vehicle ID is 3 digits LCD Display Aug 28 2010 12 20 23 LCD Display KEY to SCROLL F KEY TO EXIT LCD Display SET VEHICLE ID EN...

Страница 9: ...u to erase the SDRAM all files contained on the UTX SkidWeigh Plus Make selection Y or N and press Enter key to confirm selection and the system will automatically bring you back to the main screen in...

Страница 10: ...ter or move vehicle After few seconds system zero weight value will be calibrated and stored LCD will show Lower the empty forks to the ground The LCD display will prompt you to input known calibratio...

Страница 11: ...display will show date time System check weighing function calibration is completed System is ready to be used Overload Warning Function Optional As soon forks are lowered the LCD display will show T...

Страница 12: ...iod 8 hours End use programable 8 or 12 hours IDLING automatic unidentify true idling events within utilization factor Up to 5 valid downtime reasons applicable for material handling operation DEFAULT...

Страница 13: ...Oakville Ontario Canada L6L 0A7 www skidweigh com Loaded forks must be lowered to the ground LCD display must show date time Lift the load approximately 2 off the ground Do not use tilt side shift or...

Отзывы: