18
Integrated Technical Vision Ltd
http://www.itvsystems/com/ua
Access level - 3
Press key
[1]
. Green LED 2 switches OFF, that means code does not drive Re-
lay1.
Press key
[2]
. LED 3 switches ON, that means code drives Relay 2.
Press key
[4]
. Buzzer emits continuous beep that means unit is ready for Relay
Time editing.
Press keys
[1][9][#]
. Buzzer emits continuous beep that means unit has accepted
new value of Relay Time.
Press key
[5]
. Buzzer emits continuous beep that means unit is ready for Entry
Time editing.
Press keys
[5][5][#]
. Buzzer emits continuous beep that means unit has accepted
new value of Entry Time.
Press key
[#]
to return to Engineer code programming mode.
Enter
[1][2][#]
, Buzzer sounds continuous beep and then displays previously pro-
grammed Lockout Time.
Press
[*]
, continuous beep sounds - unit is ready for Lockout Time editing.
Press
[0][#]
, continuous beep sounds - changes are accepted.
Press
[#]
, continuous beep sounds and the unit quits Engineer programming.
User code viewing and editing
Press
[3][#]
, then
[code number][#]
OR
[user code][#]
. DLK-640Plus displays
user code. Pressing of
[#]
will return you to Engineer programming, pressing of
[*]
allows to enter new user code.
Example
If you want to change user code #3 to
[0] [6] [1] [1] [7] [5]
in Engineer code
programming mode:
Press
[3][#]
, the panel displays user code.
Press
[*]
, then
[0] [6] [1] [1] [7] [5][#]
.
User code deletion
Enter
[4][#]
then
[code number][#]
OR
[user code][#]
.
Example
If you want to delete user code #17 press
[4][#]
then
[1][7][#]
.
Panel’s reset to factory defaults
Enter
[5][#]
, then
[Engineer code][#]
.
After performing of this operation all previously programmed user codes are delet-
ed and Engineer code, Master code and code #2 are programmed according to
factory defaults.
Example
If Engineer code is
[1] [9] [8] [8]
and you want to reset DLK-640Plus stand-alone
access control panel to factory defaults, press
[5] [#]
. Buzzer utters nine sound
signals. Enter Engineer code:
[1] [9] [8] [8]
.
Alarm output activation time
Enter
[1] [1] [#]
. Unit displays value of alarm output time with buzzer and LED 2.
Press
[#]
to exit alarm output time setting. Press
[*] [new Alarm Time value] [#]
to enter new value.
Engineer code programming mode