16
Integrated Technical Vision Ltd
http://www.itvsystems/com/ua
Engineer code programming mode
Enter
[Engineers code] [#]
, factory setting - [1] [2] [3] [4] to switch to Engineer
code programming mode. Buzzer will sound several times accompanied with LEDs’
blinks. LED 1 blinks during the whole period of programming.
Engineer code can be changed as described in "Code change with [*] button"
Engineer code programming mode is described in APPENDIX "Engineer code
programming flowchart".
After Engineer code programming mode engaging you acquire the following pos-
sibilities:
“Master code” programming.
Enter
[0][#]
, then new
[Master code][#]
and confirm it:
[Master code][#]
.
New code will be accepted if it differs from any enrolled users’ codes and duress
codes.
Example
To change Master code to 7777 in “Engineer” programming mode enter
[0][#]
,
then
[7] [7] [7] [7] [#]
and once more
[7] [7] [7] [7] [#]
.
Users’ codes enrollment
Enter
[1][#]
. DLK-640Plus displays the first not-used user code number with buzz-
er and LED 2 indications. Enter
[User Code][#]
. After that you can change code
settings or move to Engineer programming mode by pressing
[#]
.
Default settings of new code are:
Code drives Relay 1
Relay Time is 255 (default time)
Door Time is 255 (default time)
Access level - 3
To view or change settings press appropriate key (see Table 1)
To exit user code settings editing mode press
[#]
button.
User code settings editing
Enter
[2][#]
. Then enter
[number]
of user code OR
[User Code]
and press
[#]
.
LEDs 2 and 3 indicate relay operation setting for this code.
Press appropriate key for parameters change (see Table 1).
The "default" value of relay time is used if you need to set equal time for many user
codes. If you are using "default" time, changing of these values causes changes of
time for all user codes, relevant to them.
Engineer code programming mode