14
Integrated Technical Vision Ltd
http://www.itvsystems/com/ua
Control Panel Operation
DLK-640Plus can operate in one of the following modes:
-
Main mode:
-
Day mode
-
Night mode
-
[*] button programming mode
-
"Engineer" code programming mode
-
"Master" code programming mode
-
Lockout mode
LED 1(red) continuously lights in the main mode. The unit performs actions, pro-
grammed for entered code in this mode. These actions are: Relay 1 activation,
Relay 2 activation, activation of both relays or opportunity to choose relay for acti-
vation.
Night mode of the unit is indicated by "slow" blinks of LED 1. Only codes with
access level 2 are valid in this mode.
To switch the unit into night mode enter code without control over any relay per-
mission (see "Engineer programming mode"). This code should have access level
2, otherwise the code will be able to switch night mode on, but unable to switch a
unit into day mode.
If duress code is entered, DLK-640Plus performs actions accordingly to user code
access level and options and switches on alarm output for programmed time. Alarm
output switches on immediately after duress code entry.
If there are no keystrokes for 40 seconds a unit returns to the main mode automat-
ically.
Program desired settings and codes before utilizing the unit.
Programming
During programming DLK-640Plus stand-alone access control unit ignores break/
opening of RTE button. Door sensor control lasts as usual.
Factory defaults
After the first switching on and after reset to factory defaults DLK-640Plus works in
the main mode with the following settings:
-
Alarm output time
10 sec
-
Lockout time
40 sec
-
Engineer code
1234
-
Master code
5678
-
User code #2
[A][A][A][A]
-
Code drives
Relay1
-
Relay time
3 sec
-
Door time
15 sec
-
Access level
3
-
Default Relay 1 time 3 sec
Programming