Integrated Technical Vision
9
Terminals Assignement
- +12V, GND - +12V power supply connection terminals;
- RTE - request-to-exit button connection terminals;
- DC - door sensor connection terminals;
- I/O - LED 2 external management (red light)
- SAB - tamper connection terminal;
- ALM - transistor alarm output for external unit connection;
- NO2, CM2, NC2 - Relay2 normally open, common and normally closed termi-
nals;
- NO1, CM1, NC1 - Relay1 normally open, common and normally closed termi-
nals.
Mounting
DLK-640Plus stand-alone access control unit is to be mounted indoors at 85%
relative humidity.
DLK640Plus mounting description:
–
Release the screw in the bottom of the cover pos a) on Figure 3
–
Slightly pull the bottom side of the cover (pos b) on Figure 3) and take it
down
–
Disconnect the keypad PCB from the base plate (connector X3)
–
Mark the position of the fixing holes on the wall, using back plate as a pat-
tern (pos c) on Figure 3
–
Drill fixing holes of the appropriate depth with 6 mm drill
–
Pull the wiring through the holes on the back plate and secure the wiring with
supplied screws
–
Connect the wires
–
Connect the keypad PCB to the baseplate with a screw.
–
Fix firmly the front cover
a)
5...10
мм
b)
Mounting
holes
Wiring
holes
GND
+12V
ALMCM1
RTE DC I/O
SAB
NC1 NO1CM2NC1NO1
J1
FA
C
T
O
R
Y
SET
T
IN
G
Keyboard Connector X2
c)
Operation