DLK640Plus

s t a n d - a l o n e   a c c e s s   c o n t r o l   p a n e l

®

Содержание DLK640Plus

Страница 1: ...Stand alone access control panel DLK640Plus s t a n d a l o n e a c c e s s c o n t r o l p a n e l ...

Страница 2: ...2 Integrated Technical Vision Ltd http www itvsystems com ua ...

Страница 3: ... the document or its part without permission of Integrated Technical Vision Ltd is prohibited Trademarks ITV is a registered trademark of Integrated Technical Vision Ltd Training and technical support Integrated Technical Vision Ltd performs training on the installation programming and utilisation of DLK 640Plus stand alone access control unit For additional in formation about the training and dis...

Страница 4: ... 10 Duress Code 12 LEDs 12 Control Panel Operation 14 Programming 14 Factory defaults 14 Default times 15 Settings displaying 15 Hardware reset to factory defaults 15 User code settings editing 20 User code change 20 User code review 20 button programming mode 21 APPENDIX 1 22 Access Control System 22 High Degree Security Access Control System 24 APPENDIX 2 28 Limited Warranty 31 ...

Страница 5: ... two execution units control by means of code entry DLK640Plus is characterized by presence of nonvolatile memory two relays alarm output one engineer code one chief code and 29 users codes Valid code intro duction allows you relay control and day night modes change The panel supports such advanced features as request to exit keypad lockout duress code two ac cess levels It has three light emittin...

Страница 6: ...codes Additional duress code for each user code Two access levels Two relays Alarm output Door sensor RTE sensor Tamper Specifications Electrical Voltage 10 15 V Power consumption Stand by 15 mA Maximal 70 mA Contact Rating Relay 5A 24 V Alarm Output 60 mA 24V Voltage ripple 500mV 12V Mechanical Weight 200 grams Dimensions 156 x 105 x 20 mm Environmental Temperature 0 55 C Relative humidity 80 at ...

Страница 7: ...view of DLK 640Plus stand alone access control panel is shown on Figure 1 1 LED1 2 LED2 3 LED3 4 built in keypad 5 blank end cover 6 control unit PCB 7 keypad PCB 8 front cover GND 12V ALM CM1 RTE DC I O SAB NC1NO1 CM2 NC2 NO2 FAC TORY SETTING Keyboard Connector X2 5 6 7 8 б 4 a 1 2 3 Operation ...

Страница 8: ...Terminals Layout Terminals layout on the main board is shown on Figure 2 below GND 12V ALMCM1 RTE DC I O SAB NC1NO1CM2NC2NO2 FACTORY SETTING Keyboard Connector X2 Panel baseplate Keypad PCB Alarm output Locking devices Door sensor RTE button 12 V power Operation ...

Страница 9: ...ndoors at 85 relative humidity DLK640Plus mounting description Release the screw in the bottom of the cover pos a on Figure 3 Slightly pull the bottom side of the cover pos b on Figure 3 and take it down Disconnect the keypad PCB from the base plate connector X3 Mark the position of the fixing holes on the wall using back plate as a pat tern pos c on Figure 3 Drill fixing holes of the appropriate ...

Страница 10: ...rmally closed con tacts while RTE button must have normally open contacts It is advisable to equip the door with mechanical door closer Electric locks and door strikes The unit has two relays with normally opened and normally closed contacts for energizing or de energizing electric locks door strikes etc Relays are activated after valid code introduction Relays can work in triggering mode program ...

Страница 11: ...onnecting it to the outer alarm system or the execut ing device with operation current less than 60 mA If door contact is connected to DC terminal alarm output will activate any time the door is opened except entry time Alarm output activates for the programmed alarm time from 1 to 254 seconds If alarm time is programmed for 0 seconds alarm output will never be active If alarm time is programmed f...

Страница 12: ...code you can program Access level from 1 to 4 define access rights programmed by Master code Code options choose relays to drive relay time door time programmed by Engineer code Duress Code Every user besides his regular code has an additional duress code independent ly of user code access level and options When this code is entered DLK 640Plus stand alone access control unit grants access accordi...

Страница 13: ...signal sounds if door is opened for five seconds before door time ending In this case you should close the door and enter code once more to start door time again The door time is programmed by means of an Engineer code Valid values are 0 253 seconds Open door state After code with door time set to 254 sec entering the door will not be supervised for unlimited time until it is closed Lockout Mode I...

Страница 14: ...ss level 2 otherwise the code will be able to switch night mode on but unable to switch a unit into day mode If duress code is entered DLK 640Plus performs actions accordingly to user code access level and options and switches on alarm output for programmed time Alarm output switches on immediately after duress code entry If there are no keystrokes for 40 seconds a unit returns to the main mode au...

Страница 15: ...u change the time of relay activation for all these codes Settings displaying Numeric values of settings are displayed by means of built in buzzer and LED 2 Nonzero digit is displayed as number of short beeps and LED 2 blinks Digits are separated by interval For instance number 235 will be displayed as follows 2 blinks of LED 2 2 beeps interval 3 blinks of LED 2 3 beeps interval 5 blinks of LED 2 ...

Страница 16: ...ramming mode enter 0 then 7 7 7 7 and once more 7 7 7 7 Users codes enrollment Enter 1 DLK 640Plus displays the first not used user code number with buzz er and LED 2 indications Enter User Code After that you can change code settings or move to Engineer programming mode by pressing Default settings of new code are Code drives Relay 1 Relay Time is 255 default time Door Time is 255 default time Ac...

Страница 17: ...ult door time Engineer code programming mode y e K y e K y e K y e K y e K n o i t c n u F n o i t c n u F n o i t c n u F n o i t c n u F n o i t c n u F y b d e w o l l o f e b o T y b d e w o l l o f e b o T y b d e w o l l o f e b o T y b d e w o l l o f e b o T y b d e w o l l o f e b o T s k r a m e R s k r a m e R s k r a m e R s k r a m e R s k r a m e R 1 1 y a l e R s e v i r d e d o C 2...

Страница 18: ...rogramming User code viewing and editing Press 3 then code number OR user code DLK 640Plus displays user code Pressing of will return you to Engineer programming pressing of allows to enter new user code Example If you want to change user code 3 to 0 6 1 1 7 5 in Engineer code programming mode Press 3 the panel displays user code Press then 0 6 1 1 7 5 User code deletion Enter 4 then code number O...

Страница 19: ... you want to set new Relay 1 Default Time value to 10 seconds press 1 3 in Engineer programming mode Unit displays current value of Relay1 Default Time with buzzer and LED 2 indications Press 1 0 To exit Engineer programming mode press Relay 2 Default Time Enter 1 4 Unit displays value of Relay 2 Default Time with buzzer and LED 2 To exit Relay 2 Default Time setting press To enter new value press...

Страница 20: ...Press 1 button sound signal confirms state change and LED 2 switches on off LED 3 switch on off Press 2 button sound signal confirms state change and LED 3 switch on off User code review Press 9 DLK 640Plus displays current User Code with buzzer and LED 2 To return to Master programming press To exit Master code programming press again If there are no keystrokes during 40 seconds the unit automati...

Страница 21: ...ame way If there was no keystrokes during 40 seconds unit returns to main or restricted mode In this case user code does not change Example User has code 1 2 3 4 5 and wants to change code to 4 3 2 1 In this case access level of the code should be 2 or 4 Press three beeps sound and LED 2 flashes RED Enter old user code 1 2 3 4 5 long beep sounds If code has access level 2 or 3 error signal sounds ...

Страница 22: ...stem DLK 640Plus can be used for access to a single room control The wiring is shown on figure below In this example Relay 1 is used to energize electric lock Terminals wiring is shown for the lock locked while been deenergized Using the lock which is unlocked while been deenergized connect it to NC terminal You can use Relay 2 terminals for additional devices engaging The input can be used for 24...

Страница 23: ...out Time 40 sec User code 2 AAAA access level 2 valid 24 hour can be changed by user relay 2 control door time 30 sec User code 3 3333 access level 4 valid day mode cannot be changed by user relay 2 control door time 30 sec User code 4 4444 access level 2 valid 24 hour can be changed by user relay 2 control door time 30 sec APPENDIX 1 ...

Страница 24: ...remises will be granted after two different codes consecutive entry The wir ing is shown on figure below Presence of two people is demanded for access to the premises as two different codes control Relay1 and Relay2 But high priority user code can have permission for individual door opening Door sensor 12V power supply RTE button outer security system input connection other facilities tamper conne...

Страница 25: ...control door time 30 sec User code 3 3333 access level 4 valid day mode cannot be changed by user relay 2 control door time 30 sec User code 4 4444 access level 2 valid 24 hour can be changed by user relay 2 control door time 30 sec User code 5 5555 access level 2 valid 24 hour can be changed by user both relay control door time 30sec A door can be opened after code 5 or code 3 4 entry in the abov...

Страница 26: ... CM1 RTE DC I O SAB NC1 NO1 CM2 NC2 NO2 Panel Use in Security systems DLK640Plus allows automatic setting unsetting of security system by means of user code entry Example Codes with Relay 1 control permission are responsible for setting unset ting of the system and codes with Relay 2 control are responsible for access to the premises The wiring is shown on Figure below APPENDIX 1 ...

Страница 27: ... by user relay 1 control relay time 10sec door time 30 sec User code 4 4444 access level 2 valid 24 hour can be changed by user no relay control door time 0 sec User code 5 5555 access level 2 valid 24 hour can be changed by user relay 2 control relay time 0sec door time 0sec Enter user code 5 and switch it from day to night mode by means of code 4 to set the system If you want to unset the system...

Страница 28: ...new code new code vacant code number new code code number or code code number or code code number or code engineer code time time value value хххххх хххххххххх indication code entry new code 13 relay 1 default time 14 relay 2 default time 15 default door time 01 relay 2 control 02 relay 1 control 03 relay control inquiry 04 relay actuation time 05 entry time 06 future used 07 relay time 08 entry t...

Страница 29: ... r e t s a m 2 0 t i x e o t t s e u q e r 3 0 4 0 5 0 7 0 8 0 9 0 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 0 3 Access levels r e t e m a r a p r e t e m a r a p r e t e m a r a p r e t e m a r a p r e t e m a r a p e u l a v e u l a v e u l a v e u l a v e u l a v s t l u a f e d y r o t c a f s t l u a f e d y r o t c a f s t l u a f e d y r o t c a f s t l...

Страница 30: ...ems com ua s s e c c a l e v e l 2 D E L 3 D E L s i e d o c y b d e g n a h c r e s u e d o m n i d i l a v 1 f f O f f O e v i t c a n i O N 2 f f O n O e v i t c a S E Y r u o h 4 2 3 n O f f O e v i t c a O N y a d 4 n O n O e v i t c a S E Y y a d ...

Страница 31: ... shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Integrated Technical Vision Ltd This warran ty contains the entire warranty Integrated Tec...

Страница 32: ...32 Integrated Technical Vision Ltd http www itvsystems com ua 030203 ...