10. ERROR CODES

 

 

      

 

FAILURE / ERROR 

CODE

ICON

Bus failure 

01 

 

Hi BUS Voltage 

02 

 

Low BUS Voltage 

03 

 

Bus Unbalanced 

04 

 

Short-circuit in BUS 

05 

 

Soft-start Inverter Failure 

11 

 

Inverter: Hi Voltage 

12 

 

Inverter: Low Voltage 

13 

 

Inverter output short circuit 

14 

Battery Very High Voltage 

27 

Battery Very Low Voltage 

28 

Over Temperature 

41 

Overload: UPS power output capacity has been exceeded. Inverter cannot 
supply output. 

43 

 

 

 

 

11. ALARMS ON LCD

 

 

      

 

ALARM Description 

ICON on LCD

Beep Alarm

Low battery 

1 / s 

Overload: hi power consumption detected at UPS output. 

2  / s 

Battery disconnected 

1 / s 

Batteries overcharged 

1 / s 

Input Cable failure 

1 / s 

EPO enable 

1 / s 

FAN failure 

1 / s 

Over Temperature 

1 / s 

Battery charger problem 

1 / s 

Input out of range in bypass mode 

1 / s 

Battery failure 

1 / s 

Battery need to be replaced 

2 / s 

Input frequency unstable for BYPASS mode 

1 / s 

EEPROM memory error 

1 / s 

 

 

BEEP ALARM 

Battery Mode: 

 

1 “Beep” every 4 seconds 

Battery Low: 

 

1 “Beep” per second 

Output Overload: 

 

2 “Beeps” per second  

UPS Failure: 

 

Continuous Beep 

By-Pass Mode: 

 

1 Beep every 10 seconds. 

Содержание EPRO 1.5K

Страница 1: ...DOUBLE CONVERSION UPS Technical information on this manual is property of INTEGRA This manual Information cannot be copied or distributed totally or partially without written approval of INTEGRA INTEG...

Страница 2: ...Inverter Technology Full Bridge isolated neutral Main Features of Full Brdige UPS Output Neutral is not connected to Input Neutral in normal Online mode That generates a floating voltage between outpu...

Страница 3: ...with care Do not block UPS ventilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT co...

Страница 4: ...ient burst immunity IEC EN 61000 4 4 Level 4 Surge immunity IEC EN 61000 4 5 Level 4 Conducted Immunity IEC EN 61000 4 6 Power frequency magnetic field immunity IEC EN 61000 4 8 Voltage Dips Short Int...

Страница 5: ...cording to the model In terms of communication you have a wide range of alternatives like RS 232 USB Ethernet LAN or AS 400 interface some of them are optional Please follow carefully this manual duri...

Страница 6: ...PS This kind of damage is not covered by warranty FIG 1 For all full bridge models 1KF 3KF 1KF CN to 3KF CN it is not allowed to connect output Neutral to system Ground This practice will generate int...

Страница 7: ...trongly affected by length and temperature Input wire must be selected and installed by qualified personnel according to local regulations 2 First time leave UPS recharging batteries during 6 hours be...

Страница 8: ...must be sure about the kind of EXBATT to be connected to UPS In case of doubts we recommend to revise product label and instructions of this manual MODELO VOLTAJE DC MODELO VOLTAJE DC MODELO VOLTAJE...

Страница 9: ...sitions or dead times In that way your hardware but also your valuable data will be safe when your PC related equipment is connected to EPRO series UPS Power output is sine wave type same as supplied...

Страница 10: ...ency as selected BATTERY MODE When AC input source is out of range Ups goes to battery mode to supply output from taking energy from batteries BYPASS If UPS is overloaded by big consuming load connect...

Страница 11: ...abnormal battery situation 2 Indicates UPS time under battery mode H hours M minutes S seconds 3 Alert triangle symbol indicates alarm or error Two 2 digits code indicates error alarm code 4 This symb...

Страница 12: ...NT FUNCTIONS AND OPTIONS CONFIGURATION MENU BY MODEL FUNCTION EPRO 1K 1 5K 2K 3K EPRO F 1KF 2KF 3KF EPRO F CN 1KFCN 2KFCN 3KFCN 00 ESC screen ESC screen ESC screen 01 Output Voltage Setting Output Vol...

Страница 13: ...____________________________________________________________________________________________ www integra ups com 1305 EPRO 1K 3K 13 MODEL EPRO F CN 1KF CN 2KF CN 3KF CN Screens for 230V models 120V mo...

Страница 14: ...__________________________________________________________________________________________________ www integra ups com 1305 EPRO 1K 3K 14 MODEL EPRO F 1KF 2KF 3KF Screens for 230V models 120V models h...

Страница 15: ...__________________________________________________________________________________________________ www integra ups com 1305 EPRO 1K 3K 15 MODEL EPRO 1K 1 5K 2K 3K Screens for 230V models 120V models h...

Страница 16: ...re 41 x Overload UPS power output capacity has been exceeded Inverter cannot supply output 43 11 ALARMS ON LCD ALARM Description ICON on LCD Beep Alarm Low battery 1 s Overload hi power consumption de...

Страница 17: ...re Batteries and charger must be inspected by qualified personnel Code 28 Active Continuous beep Very low voltage at batteries or charger failure Batteries and charger must be inspected by qualified p...

Страница 18: ...ftware CD inside the box For others software downloading is available from our website Download always software user manual and follow it carefully during software installation 14 BATTERIES MAINTENANC...

Страница 19: ...whichever is longer 5 INTEGRA or their distribution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons...

Страница 20: ...UPS Outlets 9 SNMP Smart Port 3 AC Input 10 External Battery Connector EXBATT 4 Input Breaker 11 AC Output Terminal Block 5 RJ45 Surge Protected Sockets 12 Output Breaker 6 Emergency Power Off Connec...

Страница 21: ...do del UPS Consumo Bater as Voltaje Entrada Salida Autonom a Diagnostico Fallas INDICATORS INDICADORES LCD ALARM ALARMAS Alarm Beep Alarma Sonora 1 0 A Max x 12V 9Ah x 12 12V 9Ah x 12 x Battery Mode L...

Страница 22: ...n Frequency converter mode is activated When the output voltage is adjusted to 208VAC in 220Vac models output capacity derates to 80 La capacidad en VA Watts se degrada y baja hasta el 60 en modo Conv...

Страница 23: ...r and Fault conditions Estado del UPS Consumo Bater as Voltaje Entrada Salida Autonom a Diagnostico Fallas Battery Mode Low batt Overload UPS Failure Modo Bater a Baja bater a Sobrecargas Falla N N N...

Страница 24: ...ada se mantenga entre 40 y 70 Hz Derate capacity to 60 of total capacity when Frequency converter mode is activated When the output voltage is adjusted to 208VAC in 220Vac models output capacity derat...

Отзывы: