17. ESPECIFICACIONES (1KF / 2KF / 3KF)   &   (1KF-CN / 2KF-CN / 3KF-CN)                            (2/2)

       

 
 

 

 

PRODUCT FEATURES  / CARACTERISTICAS DEL PRODUCTO

 DxWxH / Prof.*Ancho*Altura (mm)
 Net Weight / Peso Neto (kgs)

UPS MODEL: 230Vac (EUROPE)

 Prog. Outlets / Salidas prog. (*N2)

UPS MODEL: 120Vac (AMERICA)

 Prog. Outlets / Salidas prog. (*N2)

External Battery Cabinet (Tower)

 DxWxH / Prof.*Ancho*Altura
 Net Weight / Peso Neto (kgs)

UPS "Tower" Type

Unit CARTON: DxWxH (mm)
Unit Gross Weight / Peso Bruto (Kg)
Half Pallet / Medio Pallet
Full Pallet / Pallet Completo

External Battery Cabinet

Unit CARTON: DxWxH (mm)
Unit Gross Weight / Peso Bruto (Kg)
Half Pallet / Medio Pallet
Full Pallet / Pallet Completo

OPERATIONAL CONDITIONS / CONDICIONES DE OPERACIÓN

Temperature / Temperatura

(*N1): Output voltage is selectable by LCD / El Voltaje de salida es configurable entre 4 alternativas seleccionables en el LCD
(*N2): Backup time for programable outlets is configurable (in minutes) by LCD to offer longer time to critical loads connected to normal outlets
La autonomía de las salidas programables es configurable (en min.) en el LCD para dejar mayor autonomía para las salidas normales
(*N3): Converter Mode Function allows to set output frequency at constant value: 50Hz or 60Hz when input Frequency is within 40 - 70 Hz
El modo de Conversión de Frecuencia permite fijar la salida a 50 o 60Hz siempre que la frecuencia de entrada se mantenga entre 40 y 70 Hz.
** Derate capacity to 60% of total capacity when Frequency converter mode is activated.
     When the output voltage is adjusted to 208VAC (in 220Vac models) output capacity derates to 80%.
** La capacidad en VA/ Watts se degrada y baja hasta el 60% en modo "Convertidor de Frecuiencia".
     Cuando el voltaje de salida se ajusta a 208Vac (en los modelos de 220Vac) se pierde un 20% de capacidad de salida.
** Maximum working altitud is 4.000m. Over 1.000m output derates 1% every 100m.
     Altura máxima de operación es 4.000m. Sobre los 1.000m la potencia de salida disminuye un 1% cada 100m.

LAN Card SNMP type - optional / Comunicación con LAN mediante SNMP opcional

AS400 Interface (optional comm. Card) / Interfaz con AS400 (tarjeta opcional)

NA

Windows family; Linux; Unix; Mac OS

560x320x470

560x320x470

NA

50pcs

12pcs
24pcs

NA

NA

12

3KF & 3KF-CN

< 95 % RH  (non-condensing / no condensante)

0 - 40 ºC

< 45dBA @ 1 m

NA

31

41

12pcs
24pcs

13

19

30

472x230x340

30pcs
50pcs

30pcs

560x320x470

421x190x318

SCHUKO x 3

SCHUKO x 3

SCHUKO x 4

NA

NA

NA

NA

421x190x318

397x145x220

397x145x220

421x190x318

NEMA-20  x 4

NEMA-20  x 4

NEMA x 6 +TB

17

28

Technical specifications can be modified to comply with special requirements / Las especificaciones pueden bajo requerimiento adaptarse a proyectos especiales
Technical specifications may change without further notice / Por motivos comerciales o técnicos las especificaciones pueden cambiar sin previo aviso.

 Standard Outlets / Salidas Estándar

Noise Level / Ruido Producido

1KF & 1KF-CN

2KF & 2KF-CN

NA

24pcs

 Standard Outlets / Salidas Estándar

ONLINE UPS (2/2)

472x230x340

29

39

NA

NA

12pcs

Intelligent SNMP Port:

COMMUNICATION / COMUNICACION

PACKING / EMPAQUE

Rel. Humidity / Humedad Relativa

Smart RS-232 & USB

Содержание EPRO 1.5K

Страница 1: ...DOUBLE CONVERSION UPS Technical information on this manual is property of INTEGRA This manual Information cannot be copied or distributed totally or partially without written approval of INTEGRA INTEG...

Страница 2: ...Inverter Technology Full Bridge isolated neutral Main Features of Full Brdige UPS Output Neutral is not connected to Input Neutral in normal Online mode That generates a floating voltage between outpu...

Страница 3: ...with care Do not block UPS ventilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT co...

Страница 4: ...ient burst immunity IEC EN 61000 4 4 Level 4 Surge immunity IEC EN 61000 4 5 Level 4 Conducted Immunity IEC EN 61000 4 6 Power frequency magnetic field immunity IEC EN 61000 4 8 Voltage Dips Short Int...

Страница 5: ...cording to the model In terms of communication you have a wide range of alternatives like RS 232 USB Ethernet LAN or AS 400 interface some of them are optional Please follow carefully this manual duri...

Страница 6: ...PS This kind of damage is not covered by warranty FIG 1 For all full bridge models 1KF 3KF 1KF CN to 3KF CN it is not allowed to connect output Neutral to system Ground This practice will generate int...

Страница 7: ...trongly affected by length and temperature Input wire must be selected and installed by qualified personnel according to local regulations 2 First time leave UPS recharging batteries during 6 hours be...

Страница 8: ...must be sure about the kind of EXBATT to be connected to UPS In case of doubts we recommend to revise product label and instructions of this manual MODELO VOLTAJE DC MODELO VOLTAJE DC MODELO VOLTAJE...

Страница 9: ...sitions or dead times In that way your hardware but also your valuable data will be safe when your PC related equipment is connected to EPRO series UPS Power output is sine wave type same as supplied...

Страница 10: ...ency as selected BATTERY MODE When AC input source is out of range Ups goes to battery mode to supply output from taking energy from batteries BYPASS If UPS is overloaded by big consuming load connect...

Страница 11: ...abnormal battery situation 2 Indicates UPS time under battery mode H hours M minutes S seconds 3 Alert triangle symbol indicates alarm or error Two 2 digits code indicates error alarm code 4 This symb...

Страница 12: ...NT FUNCTIONS AND OPTIONS CONFIGURATION MENU BY MODEL FUNCTION EPRO 1K 1 5K 2K 3K EPRO F 1KF 2KF 3KF EPRO F CN 1KFCN 2KFCN 3KFCN 00 ESC screen ESC screen ESC screen 01 Output Voltage Setting Output Vol...

Страница 13: ...____________________________________________________________________________________________ www integra ups com 1305 EPRO 1K 3K 13 MODEL EPRO F CN 1KF CN 2KF CN 3KF CN Screens for 230V models 120V mo...

Страница 14: ...__________________________________________________________________________________________________ www integra ups com 1305 EPRO 1K 3K 14 MODEL EPRO F 1KF 2KF 3KF Screens for 230V models 120V models h...

Страница 15: ...__________________________________________________________________________________________________ www integra ups com 1305 EPRO 1K 3K 15 MODEL EPRO 1K 1 5K 2K 3K Screens for 230V models 120V models h...

Страница 16: ...re 41 x Overload UPS power output capacity has been exceeded Inverter cannot supply output 43 11 ALARMS ON LCD ALARM Description ICON on LCD Beep Alarm Low battery 1 s Overload hi power consumption de...

Страница 17: ...re Batteries and charger must be inspected by qualified personnel Code 28 Active Continuous beep Very low voltage at batteries or charger failure Batteries and charger must be inspected by qualified p...

Страница 18: ...ftware CD inside the box For others software downloading is available from our website Download always software user manual and follow it carefully during software installation 14 BATTERIES MAINTENANC...

Страница 19: ...whichever is longer 5 INTEGRA or their distribution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons...

Страница 20: ...UPS Outlets 9 SNMP Smart Port 3 AC Input 10 External Battery Connector EXBATT 4 Input Breaker 11 AC Output Terminal Block 5 RJ45 Surge Protected Sockets 12 Output Breaker 6 Emergency Power Off Connec...

Страница 21: ...do del UPS Consumo Bater as Voltaje Entrada Salida Autonom a Diagnostico Fallas INDICATORS INDICADORES LCD ALARM ALARMAS Alarm Beep Alarma Sonora 1 0 A Max x 12V 9Ah x 12 12V 9Ah x 12 x Battery Mode L...

Страница 22: ...n Frequency converter mode is activated When the output voltage is adjusted to 208VAC in 220Vac models output capacity derates to 80 La capacidad en VA Watts se degrada y baja hasta el 60 en modo Conv...

Страница 23: ...r and Fault conditions Estado del UPS Consumo Bater as Voltaje Entrada Salida Autonom a Diagnostico Fallas Battery Mode Low batt Overload UPS Failure Modo Bater a Baja bater a Sobrecargas Falla N N N...

Страница 24: ...ada se mantenga entre 40 y 70 Hz Derate capacity to 60 of total capacity when Frequency converter mode is activated When the output voltage is adjusted to 208VAC in 220Vac models output capacity derat...

Отзывы: