Scope of Delivery 

Please check the scope of delivery before initial operation: 
 

 

INSYS GSM 4.2 easy 

 

PC connection cable 9/9 pin (RS232) 

 

User Manual INSYS GSM 4.2 

 

Additional Manual INSYS GSM 4.2 easy 

 

CD-ROM  

 
In case the content is not complete, please contact your supplier. Please check the 
device for shipping damage. Please also refer to your supplier if damage exists. 
Please keep the packaging material for dispatch or storage. 
 

Optional Accessories 

 

 

Adapter cable D-SUB 9 pin, male to 9 pin, male 

 

GSM aerial 

 

Outside mounted aerial, magnetic base aerial or patch aerial 

 

Connection cable GSM easy 500 for connecting the INSYS GSM 4.2 easy to 
a Moeller easy 500/700 (Art.-Nr.: 31-02-02-011) 

 

Connection cable GSM easy 800 for connecting the INSYS GSM 4.2 easy to 
a Moeller easy 800/MFD (Art.-Nr.: 31-02-02-012) 

 

Содержание GSM 4.2 easy

Страница 1: ...Add On Manual INSYS GSM 4 2 easy Oct 08...

Страница 2: ......

Страница 3: ...rademark of Microcom Inc IBM PC AT XT are registered trademarks of International Business Machine Corporation INSYS is a registered trademark of INSYS MICROELECTRONICS GmbH Windows is a registered tra...

Страница 4: ...Object Instance 15 3 3 3 Setting an Object Instance 17 3 3 4 Status Query 18 3 3 5 Status Change 18 3 4 New History Entries 19 4 Initial Operation 20 4 1 Installation Overview 20 4 1 1 Installation fo...

Страница 5: ...Abort 28 5 6 Tabs 29 5 7 Basic Settings 29 5 7 1 GSM Connection 30 5 7 2 System Monitoring 32 5 7 3 Date Time 32 5 7 4 Serial Interface 32 5 8 Moeller easy Settings 33 5 8 1 Alias Configuration 34 5...

Страница 6: ...ce for shipping damage Please also refer to your supplier if damage exists Please keep the packaging material for dispatch or storage Optional Accessories Adapter cable D SUB 9 pin male to 9 pin male...

Страница 7: ...GSM 4 2 easy compact differs from the INSYS GSM 4 2 easy this will be mentioned in particular in the respective sections Supported Moeller easy versions The following easy models are supported easy 5...

Страница 8: ...ring of the easy object instances This message can also be per formed automatically refer also to section 3 2 2 Setting of the easy object instances This can be done from a mobile phone or via a dial...

Страница 9: ...vents unauthorized persons without knowledge of the exact password from remotely accessing the compact controller The LCD display needs to be in its original state before the Moeller easy controllers...

Страница 10: ...l register M1 can be allocated the alias waste water pump1 If an individual wants to activate the wastewater pump via mobile phone using an SMS he does not need to know that the register 1 must be use...

Страница 11: ...restart of the device Note Using the alarm inputs The usage of the 20 alarm inputs is independent from the functionality of the IN SYS GSM 4 2 easy Behaviour after reset or power up After a reset or...

Страница 12: ...ue of an object instance and to send it automatically via SMS A periodic SMS can be sent in hourly intervals of 1 to 255 h After this time has ex pired the set object instance is read out and the valu...

Страница 13: ...an object short name its instance a and finally the value itself If an alias was defined for periodically transmitted object instances this alias is entered in the SMS text instead of the object shor...

Страница 14: ...4 2 easy During this time no polling of the monitored object instances is performed function Value monitoring All SMS commands must have the following syntax password command CN reply CN means Callbac...

Страница 15: ...stead of the SMS with the current value The specification of the character string CN is required If the reply should be sent to another number than the sender number of the monitor command an addition...

Страница 16: ...Z Time U Example 1 Query of the object instance M12 MONITOR M12 CN In this case an SMS is sent to the INSYS GSM 4 2 easy which includes the com mand for the query of object instance M12 The reply SMS...

Страница 17: ...logue double word register MD 2147483648 to 2147483647 Valid objects for the easy 500 700 are Object Object short name Valid values Digital registers M 0 or 1 Digital registers N 0 or 1 Example 1 Sett...

Страница 18: ...e entered see previous example The response may contain the following Status Meaning RUN The easy device is in operating mode RUN STOP The easy device is in operating mode STOP NO SUCCESS The easy dev...

Страница 19: ...tended functionality of the INSYS GSM 4 2 easy there are several additional entries in the history memory Cause Detail Meaning PLC ERROR When communicating with the easy device there was no response a...

Страница 20: ...ble refer to Optional Accessories in the section Scope of Delivery on page 6 Alterna tively the 30 cm long INSYS adapter cable may be used The connection of the connection cables is described in the r...

Страница 21: ...le female Connect the GSM antenna 3 Connect the power supply to the terminals 10 60 VDC and the minus pole to GND Switch the device on 4 Initialization starts LED Connect is on for approx 4 seconds Af...

Страница 22: ...If the INSYS GSM 4 2 easy does not respond to the transmission of commands select the button Synchronize RS232 to automatically adapt the baud rate and the data format 7 Enter the PIN number will be s...

Страница 23: ...e antenna location needs to be changed 4 3 Troubleshooting 4 3 1 No response on commands The INSYS GSM 4 2 easy and the terminal device configuration PC or con troller have to operate the serial inter...

Страница 24: ...cult signal conditions change the an tenna location The response 99 indicates that no field strength can be detected e g for network failure defective antenna The signal quality is indicated with an u...

Страница 25: ...you are not logged in check whether the device expects a PIN by entering the command AT CPIN in the terminal window The responses mean READY No further input necessary SIM PIN Enter PIN of the SIM car...

Страница 26: ...nternet for free download http www insys tec de The software can also be found on the supplied CD ROM 5 2 Help The context sensitive help is available any time via the key F1 or the menu Help Help als...

Страница 27: ...e printed or saved as text file Note Read out the settings of your device and have this overview ready when contacting the hotline 5 3 7 Send Receive Protocol All current settings of the HSComm are cl...

Страница 28: ...GSM network if the PIN is stored 5 5 4 Reset Software reset of the INSYS GSM 4 2 easy Afterwards the device re registers at the GSM network if the PIN is stored 5 5 5 Synchronize The serial interface...

Страница 29: ...on Send values The functions are described in the following chapters provided they are relevant for the easy version The factory settings of all other settings should remain unchanged as they are not...

Страница 30: ...issing PIN of the SIM card is locked after repeated false attempts To unlock the PUK which you find in the contract docu ments of your GSM provider is required Remove the SIM card and enter the PUK us...

Страница 31: ...idered by the query and can therefore not be processed by the controller 5 7 1 5 Connection Attempts The number of attempts to connect if the remote terminal does not answer can be specified This sett...

Страница 32: ...YS GSM 4 2 easy can send an Alive message to the entered phone num ber as SMS message daily weekly or monthly The LED Status is flashing during the dispatch 5 7 2 4 Power Up SMS If this function is ac...

Страница 33: ...ic SMS Depending on the selected compact controller the speed of the serial interface is set to 4800 bps or 9600 bps When the selection is changed the complete con figuration for the Moeller easy func...

Страница 34: ...be transferred once more 5 8 1 Alias Configuration After clicking the button Configure a window is displayed under the field Alias which is used to allocate aliases to up to 30 object instances The t...

Страница 35: ...is turned on in the main window Settings from 1 to 255 seconds are possible for the monitoring interval Settings from 1 to 255 minutes are possible for the intervals between sending at tempts Up to 10...

Страница 36: ...eriodic SMS is turned on in the main window In the text field Alias an object instance which has already been allocated an alias can be selected optionally If this is not preferred or if no alias is d...

Страница 37: ...this serial interface now has no connection to another program but maintains the connection The program EASY SOFT can now be started and program the easy device as if it was connected to a local seria...

Страница 38: ...imeout for Communication must be in creased to at least 1000 ms For the easy 800 and MFD devices the Timeout for Communication must be in creased to at least 1000 ms After the settings were changed th...

Страница 39: ...7 Declaration of Conformity Ende der St ckliste...

Отзывы: