INSYS Modem 56k small INT 2.0/USB 1.0
S Registry
June 06
73
10
S Registry
S registries may be read and written using the
ATS<n>
command. (See Chapter 9
"
AT
Command Set", command
ATS<n>
) Certain S registries may only be read; into
others only a particular range of values may be entered.
If the range of values is exceeded, the modem will report
OK
, although the value
was not accepted. We therefore recommend to immediately check modifications
by reading (
ATS<n>?
).
Note:
*
These registries are stored in the user defaults with
AT&W0
or
AT&W1
.
10.1
Overview S Registry
Register
Function
Units
Range
Default
S0*
Number of ringing tones until automatically going off-
hook
Ringing
tones
0-5 5
S1 Ringing
tone
counter
Ringing
tones
0-255 0
S2* Escape
ASCII
0-255 43
S3 Return
ASCII
0-127 13
S4 Linefeed
character
ASCII
0-127 10
S5 Backspace
character
ASCII
0-255 8
S6*
Waiting period dial tone
s
4-7
4
S7*
Waiting period carrier signal
s
0-100
60
S8* Dial
tone
delay
s
1-7 2
S9*
Reaction time carrier signal
0.1 s
1-255
6
S10*
Time period between lost carrier signal and hang up
0.1 s
20-254
20
S12*
Transmission clock of the ESC characters
0.02 s
0-255
50
S13*
Number of dialing attempts to send the message
1-12
3
S14* General
settings
138
S15* DTC
Time
Settings
1s
0-255 0*
S17*
Initial character for remote configuration
0-127
42
S21*
Settings for V24
116
S22*
Speaker system settings
75h (117)
S24*
Time period until switching into sleep mode
s
0-255
0
S25
Time period for DTR signal
0.01 s
0-255
5
S26
Time period between RTS/CTS
0.01 s
0-255
1
S27* General
settings
-
137
S29
Time period for modifier
“
Flash
”
10
ms
17
17