Functions
INSYS Modem 56k small INT 2.0/USB 1.0
34
June 06
5.8.3.2
Operation
Establishing a connection to the modem.
The connection to the modem is established.
The modem responds to an incoming call.
You must now enter the “Remote Password”, which is
identical to the password for the remote configuration.
(default:
QWERTY
)
After the password has been entered correctly, the modem
hangs up and after about 10 seconds dials the stored phone
number. Altogether, 3 dialing attempts with a pause of 10
seconds between each attempt are performed.
If the entered password was incorrect, the connection is ter-
minated and thus prevents unauthorized access to the con-
nected device.
After that, a normal data connection is established.
ATD <Renumber>
OK
No Carrier
Callback in
Progress
Connect
SECURITY CALLBACK
REMOTE PASSWORD:
QWERTY
No Carrier