INSYS Modem 56k small INT 2.0/USB 1.0
Functions
June 06
35
5.9
Data Transmit Controller (Idle Connection Control)
The Data Transmit Control (DTC) is a function integrated in
the firmware which monitors the data transmission in
online mode. This function prevents the modem to stay
online for an unlimited amount of time, although no data is
being transmitted anymore.
5.9.1
Activation
The activation takes place in the S15 registry. Any time pe-
riod between 1 and 255 seconds may be set.
5.9.2
Mode of Operation for the “Timer”
The timer will run immediately after the modem goes off-
hook. After the set time has been reached, a RESET is per-
formed.
The timer is reset by each byte that is sent via the serial in-
terface.
Note:
The timer will run immediately after the modem
goes off-hook. We therefore strongly recommend
to not setting any times below 30 seconds.
In remote mode, idle connection control at the mo-
dem must be deactivated to prevent the connec-
tion from being interrupted after the timer has run
out.
The remote data transmission will not reset the
timer.
ATS15=<n>