INSYS ISDN TA 4.0
ISDN Error Messages
1.
Start your terminal program.
2.
Activate hardware handshake in the terminal program.
3.
Configure the baud rate of the serial interface to 115200 and the data
format to 8N1.
4.
Open the serial interface, to which the INSYS ISDN TA 4.0 is
connected.
5.
Type in "
AT
" and confirm with "Enter".
The INSYS ISDN TA 4.0 replies with
OK
.
If the INSYS ISDN TA 4.0 does not respond, check the connection and
if the device receives power at all. Continue with step 2.
6.
Check the version of the currently used firmware by entering the
command AT**ver.
The INSYS ISDN
firmware, e.g.:
HUX0530 V1.027 Jun 18 2007 16:30:57
TA 4.0 displays the version of the currently used
7.
A 4.0 replies "
Erasing Flash Eprom now.
Please wait…
"
replies "
Send your XMODEM transfer now
(Ctrl-X aborts) …
"
e file transfer protocol 1k-XMODEM
pload of the
to all AT
will be returned.
Enter
AT**FLASH
to start the firmware upload.
The INSYS ISDN T
The INSYS ISDN TA 4.0
8.
Send the firmware file with th
using the terminal program.
If you do not send a firmware file, the INSYS ISDN TA 4.0 will
terminate the procedure after approx. 60 seconds.
The INSYS ISDN TA 4.0 indicates the successful u
firmware with e.g.:
Loading procedure ended successfully.
If the firmware update fails, the INSYS ISDN TA 4.0 responds
commands (like e.g.
at**ver
) with the reply:
ERROR: BOOT LOADER ACTIVE.
Configure the baud rate to
115.200 bps in any case. If you only enter
AT
,
OK
77