background image

2

 
 

 

DL169-IN-B – The circuit

Radiomodems DL169-IN-B 

and its open version

 DL169-IN 

are built by the interface and supply card

RMO148 

and the radiomodem

 

module 

DL169

.

 

The 

RMO148

  card realises the following functions:

-

 

Power supply conditioning

. A step-down switching regulator give a stabilised voltage of 5 Vdc from an 

      input voltage between 8 to 36 Vdc. It feeds directly the RS232/RS485 interfaces and, through a drop dio-

      de, the RF power amplifier. A 3.3 Vdc linear regulator is used for the DL 169 module.

-

 

Optoisolated input

 for digital input requires a DC input from 5 to 24 V or  AC input from 3.5 to 20 V.

The input impedance is of 2.2 k

, resistive.

-

 

Relay Output

, normally 

Open

, can manage a 28Vac 0.5 A current or 60Vdc 1 A current

-

 

RS232

 and 

RS485

 interfaces both on the 

D-shell f

emale

 connector

. The interface selection is achieved

by configuration software trough electronic switch. As shown in the following Fig. 1 the RS 232

interfaces utilises the connector pins from 2 to 8 while the RS 485 utilises the pins Nos. 1 and 9.

-

 

Radiomodem status 

 with a bi-colour LED normally 

green

. The data flow into or out the unit causes the

color 

change

 (from 

green

 to 

orange

) of this LED. During the configuration process this Led is 

orange

.

A second 

Red 

Led is turned on during the transmission.

-

 

Antenna connection

 with a 

BNC female connector

.

 

DL169 MODULE – 

The

 

DL169 Radiomodem used in this application is programmed with a specific

firmware version using the RTXEN, CONFIG, CH0, CH1, CH2 criteria to manage respectively:

-

 

Optoisolated Input

-

 

Output DATA Led

-

 

Relay output

-

 

RS 232 enable

-

 

RS 485 enable

The remaining criteria retain the original features. Detailed information on the module are available on the

DL169 manual.

 

                       

CE     DL169-IN-B        

RADIOMODEM  VHF

      DL169-IN      CE

The equipment is FREE USE for telemetry & command, AMR, tracing and tracking of goods

Regulatory standards:  EN 300 220-1 v2.3.1 , EN 300 220-2 v2.3.1 ,  EN 60950-1: 2001+All A11 2004 ,

EN 301 489-1/3

Содержание DL169-IN

Страница 1: ...he not received messages address reversing for the answer ECHO NAK to DTE at the end of repetitions address to DTE and so on These devices assembled with SMT components in the industrial temperature r...

Страница 2: ...ectronic switch As shown in the following Fig 1 the RS 232 interfaces utilises the connector pins from 2 to 8 while the RS 485 utilises the pins Nos 1 and 9 Radiomodem status with a bi colour LED norm...

Страница 3: ...nd electrically connected to the TNC ground simulates the ground plane and allows the utilisation of the 4 antennas ANT119 TNC shortened or ANT169L TNC full length For maximum efficiency in this case...

Страница 4: ...e communication network must be configured with these functions to allow the communication process because the improvement of the reliability of the communication is obtained lengthening the preamble...

Страница 5: ...Clock data in the packet A feature for specific application not available in the standard units LBT Listen Before Talk Before transmitting the module measure disturbing signal on the radio channel and...

Страница 6: ...the correct addressing of each packet The addressing is made by some additional bytes preceding the message in the following order One System Code Byte 1 255 One Flag byte with the bit having the foll...

Страница 7: ......

Страница 8: ......

Страница 9: ...1 1 JP6 HEAD6 2 JP1 JP2 RF BNC 1 JP5 100 H A7502HY 101M 1 L1 L3VEGW 1 LD1 L934RD 1 LD2 HMHAA280 1 OPT1 BC846B 5 Q1 Q2 Q4 Q6 Q8 BC856B 2 Q5 Q7 FDN5618P 1 Q3 2 7 1 1 R18 3 3 1 2 R13 R14 10 1 3 R37 R38 R...

Страница 10: ......

Страница 11: ......

Отзывы: