background image

5

 

 DL169 -IN-B  -  CONFIGURATION

The Radiomodem setup is achieved by the 

Configuration Software DL148SW-IN

 dedicated to 

all

 devices DL*** series. This software is

releasable from our Internet website at URL: 

www.ere-online.it

Follow the configuration procedure:

1 - 

Install the configuration software on your Personal computer. The required OS are Windows ’95 

 XP and the PC 

must have

 a RS-232 Port.

2 - 

Connect the radiomodem RS-232 port to the computer COM port with a 

straight cable (NO Null Modem)

.

3 –

 Start the software, open the 

Option menu

 to select the 

COM Port

 and the 

operating Band

 of the radiomodem in according

      to the owned model.

4 – 

Power On

 

the radio modem and click on the button '

Turn ON'

 in the configurator. The system go into configuration mode indicated by

      the ON/DATA LED color change from green to orange.

5 –

 Follow the online help of the configuration software to achieve the complete radiomodem setup.

6 – 

The configuration parameters can be saved in a file for subsequent use or control.

7 –

 After the configuration process quit the setup procedure by clicking on the button '

Turn OFF

' in the configurator or by removing the power.

The configuration software shows three pages: 

BASIC, ADVANCED

 and 

LINK TEST

 for the communication test after the setup.

BASIC:

SYSTEM CODE

 – It defines univocally the radio network. Of course 

all

 radiomodems of the network 

must have

 the 

same System code

.

RX and TX Frequency

 -The receiving and transmitting frequency. The frequency values are indicated in 

kHz

 and are predefined. The channel

                                         is selected clicking on the related box. If two or maximum three channels are selected, the 

Adaptive  Frequency Agi-

                                         lity

 function is introduced  to choose the less disturbed channel.

RTC upd

 – If selected,  allows the send of the 

Real Time Clock

 

data

 in the packet. A feature for specific application, 

not available

 in the

                    standard units.

LBT – Listen Before Talk 

. Before transmitting the module measure disturbing signal on the radio channel and start the transmission only if

            it is lower than a threshold value of- 100 dBm @ 25 kHz or -103 dBm @ 12,5 kHz.

BROAD

 -  If selected, 

all radiomodem release the received packet

. The 

target address

 is not considered but 

necessary

 to allow the usage as

                   

digipeater

 and the 

remote configuration

, if requested. Of course the 

Its address

 must be different for each radiomodem. If the

                   Broad  option is unselected 

only the addressed modem release the packet 

to the DTE. The utilised addresses may be  set in confi-

                   guration (see Advanced page) or given by DTE if 

Addr from DTE

 is chosen; in this case the address precede the sending message.

                   Please see the Addr from DTE paragraph for more information.

POWER – 

RF power output. An 

H (High)

M (Medium)

 or 

L (Low)

 power level choice is available clicking on the box.

FLOW CONTROL – 

In 

RS-232

 mode controls, via the 

CTS criteria

, the buffer loading. If selected, the buffer dimension is 

slightly lower

 than

                                     

448 byte

. Do not select for message of  448 bytes length or for 

RS-485

 mode.

RS485 – 

choose between 

RS232

 or 

RS485

 interface.

TIME DTX –

 Configure the delay time between the end of the last character of the incoming data and the start of the transmission cycle. If the

                        DTE inserts a (variable) delay time between the bytes of a packet, the appropriate choice of this time avoids the cutting off of the
                        message. An example of this phenomenon can be seen using Hyperterminal

 

to send a packet. If Flow Control is used  this time is

                        

not considered

.

BAUD RATE DTE – 

Set the 

RS-232

 or the 

RS-485

 serial port speed. The possible speed range is from 1,200 bps to 38,400 bps. Parity selection

                                     clicking the desired box.

  

DIG IN REPET. TIME

 – Defines the time between successive transmission of the digital input state. Its range from 

0

disabled

, to 

60 minutes

.

Содержание DL169-IN

Страница 1: ...he not received messages address reversing for the answer ECHO NAK to DTE at the end of repetitions address to DTE and so on These devices assembled with SMT components in the industrial temperature r...

Страница 2: ...ectronic switch As shown in the following Fig 1 the RS 232 interfaces utilises the connector pins from 2 to 8 while the RS 485 utilises the pins Nos 1 and 9 Radiomodem status with a bi colour LED norm...

Страница 3: ...nd electrically connected to the TNC ground simulates the ground plane and allows the utilisation of the 4 antennas ANT119 TNC shortened or ANT169L TNC full length For maximum efficiency in this case...

Страница 4: ...e communication network must be configured with these functions to allow the communication process because the improvement of the reliability of the communication is obtained lengthening the preamble...

Страница 5: ...Clock data in the packet A feature for specific application not available in the standard units LBT Listen Before Talk Before transmitting the module measure disturbing signal on the radio channel and...

Страница 6: ...the correct addressing of each packet The addressing is made by some additional bytes preceding the message in the following order One System Code Byte 1 255 One Flag byte with the bit having the foll...

Страница 7: ......

Страница 8: ......

Страница 9: ...1 1 JP6 HEAD6 2 JP1 JP2 RF BNC 1 JP5 100 H A7502HY 101M 1 L1 L3VEGW 1 LD1 L934RD 1 LD2 HMHAA280 1 OPT1 BC846B 5 Q1 Q2 Q4 Q6 Q8 BC856B 2 Q5 Q7 FDN5618P 1 Q3 2 7 1 1 R18 3 3 1 2 R13 R14 10 1 3 R37 R38 R...

Страница 10: ......

Страница 11: ......

Отзывы: