background image

1

CE     DL169-IN-B        

RADIOMODEM  VHF

      DL169-IN      CE

General Informations:

DL169-IN-B

 is a VHF simplex/half-duplex high quality radiomodem with an output power of 

200 mW

ERP

 with a dedicated 

λ

/4

antenna mod. ANT169L, or a 

vertical dipole

 mod. ANT169DV, operating on six 12,5 kHz channels or three 25 kHz channels in the

169.400 – 169.475 MHz

 band in according to the European Decision 2005/928/CE. These products are characterised by 

FREE USE

.

The radiomodem is enclosed in an extruded aluminium box containing the RS232/RS485 interface and supply unit card RMO148.

DL169-IN

 defines the same device without the box while 

DL169

 is the basic unit without the 

RS232/485 

interface and supply. In

this case a direct TTL interfacing is required and it represents the more favourable solution for a direct microcontroller connection.

The following models 

DL169-IN-B-Y3

DL169-IN-Y3

 and 

DL169-Y3

 are the same devices equipped with a 

three elements Yagi

antenna

.

All the Radiomodems are fully transparent to the user and configurable from the PC by dedicated software for the desired functions.

Features:
-

 

Store & Forward

 mode with 

448 Bytes 

maximum 

Buffer size

-

 

ON/OFF switching

 controlled via 

DTR criteria

-

 

Low power consumption

 in both 

RX

 and 

TX 

 mode with selectable 

Power Saving

 

mode

 from configuration software

-

 

Broadcasting Mode

 or 

Address management

 through configuration software or directly from DTE

-

 

Digital Repeater (digipeater) Mode

 to permit communications between two or more hidden stations

-

 

Remote programming 

 of the devices  and channel selection from DTE

-

 

More sophisticated charachteristic

 as : ACK and repetition of the not received messages, address reversing for the answer,

ECHO, NAK to DTE at the end of repetitions, address to DTE and so on.

These devices

assembled with

 SMT 

components 

in the industrial temperature range, 

is particularly suitable for

 Low-Cost 

radio

networks

 

in which the

 battery or solar cells

 supply require a low power consumption together an high quality product

.

 

General

Operating band

Channel number

Canalisation

Modulation

Radio data rate (Tx / Rx)

Frequency stability

Supply voltage

Rx consumption

Tx consumption

Consumption DTR OFF
Antenna

Dimension H x W x D

Operative temperature

Reference Directives

Out switch aux

Digital input

169.400 - 169.475 MHz
3 @ CH 25 kHz , 6 @ CH 12.5 kHz –
under European Decision 2005/928/CE
12.5 kHz or 25 kHz
9K00F1D or 18K0F1D
4,800 bps @ 12.5 kHz – 9,600 bps @ 25 kHz
±500 Hz

 36 Vdc with limited source power

~ 30 mA @ 12 Vdc – RS232/485 Relay OFF
~ 300 mA
< 1 mA

λ

/4 - 

λ

//2 o 3 elements Yagi

100 x 90 x 40 mm ( 3.94 x 3.54 x 1.58 inches)
 –30 

 +70 °C  ( -22 

 158 °F)

EN 300 220-1 v2.3.1 , EN 300 220-2 v2.3.1

N.O. 28 Vac @ 0,5 A o 60 Vdc @ 1 A

 24 Vdc or 3.50 

 20 Vac. Zinp: 2.2 k

 

Transmitter

Output Power

Frequency deviation

Output power stability

Adjacent channel power

Ch. adjacent transitory power

 

Receiver – Class 2 - LBT and Agility

 

Sensitivity @ BER< 10

-2

Aadjacent channel attenuation

Blocking

Interface

Data rate (Interface)

Data format (standard)

Operative modality

0.20 W

ERP

  (DL169-IN-B)

0.5 W

ERP  

(DL169-IN-B-Y3)

± 1.8 kHz @ 12,5 kHz  -
± 3.6 kHz @ 25 kHz
±1.5 dB
compliant EN 300 220-1
compliant EN 300 220-1

<-110 dBm @ 12.5 kHz
<-107 dBm @ 25 kHz
compliant EN 300 220-1
compliant EN 300 220-1

RS 232 e RS 485
1,200 to 38,400 bps
Asynchronous 8,N,1- 8,E,1-8,O,1
Simplex or half-duplex

RS 232-RS 485

INT

1 INPUT , 1 OUTP.

GALVANICALLY

ISOLATED

All stated specifica-
tions are subjected to
change without notice
or obligation.

Содержание DL169-IN

Страница 1: ...he not received messages address reversing for the answer ECHO NAK to DTE at the end of repetitions address to DTE and so on These devices assembled with SMT components in the industrial temperature r...

Страница 2: ...ectronic switch As shown in the following Fig 1 the RS 232 interfaces utilises the connector pins from 2 to 8 while the RS 485 utilises the pins Nos 1 and 9 Radiomodem status with a bi colour LED norm...

Страница 3: ...nd electrically connected to the TNC ground simulates the ground plane and allows the utilisation of the 4 antennas ANT119 TNC shortened or ANT169L TNC full length For maximum efficiency in this case...

Страница 4: ...e communication network must be configured with these functions to allow the communication process because the improvement of the reliability of the communication is obtained lengthening the preamble...

Страница 5: ...Clock data in the packet A feature for specific application not available in the standard units LBT Listen Before Talk Before transmitting the module measure disturbing signal on the radio channel and...

Страница 6: ...the correct addressing of each packet The addressing is made by some additional bytes preceding the message in the following order One System Code Byte 1 255 One Flag byte with the bit having the foll...

Страница 7: ......

Страница 8: ......

Страница 9: ...1 1 JP6 HEAD6 2 JP1 JP2 RF BNC 1 JP5 100 H A7502HY 101M 1 L1 L3VEGW 1 LD1 L934RD 1 LD2 HMHAA280 1 OPT1 BC846B 5 Q1 Q2 Q4 Q6 Q8 BC856B 2 Q5 Q7 FDN5618P 1 Q3 2 7 1 1 R18 3 3 1 2 R13 R14 10 1 3 R37 R38 R...

Страница 10: ......

Страница 11: ......

Отзывы: