background image

 ERE Stradella Italy                                                                                                                                    DL169-IN-B

3

Products and ancillary

 :

 

 

 

The equipment is FREE USE for telemetry & command, AMR, tracing and tracking of goods

Regulatory standards:  EN 300 220-1 v2.3.1 , EN 300 220-2 v2.3.1 ,  EN 60950-1: 2001+All A11 2004 ,

EN 301 489-1/3

 ANTENNA: SELECTION AND CONNECTION

Indoor use:

1)     Use the 

λ

 / 4

 models, ANT119/BNC (shortened) or ANT169L/BNC (full length) with BNC male connector to be inserted

directly in the antenna output of the Radiomodem. If the Radiomodem is supported on a plan,  provide a right angle adapter

BNC M / F to keep the antenna vertical.

2)

 

The Radiomodem can be inserted into a plastic or metal box (preferably). Provide a 13 mm hole to fix the panel TNC female

connector of an extension cable BNC / M-TNC / F and plug the BNC male on the Radiomodem antenna connector.

3)

 

Improved efficiency may be obtained using the vertical dipole antenna ANT169DV. This is supplied with 5 meters of low loss

coaxial cable and don’t requires the ground plane so may be installed in the most favourable mode.

Outdoor use

:

For external applications the Radiomodem need to be inserted into suitable containers for IP67 protection or better. These solutions

can be used:

1)

 

Close the Radiomodem in a plastic or, better, metal container. Provide a 13 mm hole to fix the panel TNC  female connector of

an extension cable BNC / M-TNC / F and plug the BNC male on the Radiomodem antenna connector. Take care to assure an

efficient electric contact between the ground of the panel TNC female connector and the metallic box. If the container is of an

insulating material, the absence of the ground plane for the 

λ

/4 antennas decreases the radiation efficiency. To minimise this

decreasing in efficiency a metal strip or a wide wire placed in the internal side of the box and electrically connected to the TNC

ground, simulates the ground plane and allows the utilisation of the 

λ

/4

 antennas ANT119/TNC (shortened) or ANT169L/TNC

(full length). For maximum efficiency in this case the vertical dipole ANT169DV is recommended.

2)     The Radiomodem will be contained in a plastic or metal box with IP67 protection or better. Provide the required holes on the

        bottom side of the box to fix the wall-pass cable for both antenna and supply/serial line cables. It’s possible to use the vertical

        dipole antenna ANT 169DV or, in the Y3 suffix versions, the 3 elements Yagi antenna WY 155 3N to perform both the

        directivity feature and a reception gain of 3 – 4 dB, keeping the maximum transmitted ERP power within 500 mW.

 NOTE ON POWER SUPPLY

The Radiomodem DL169 or DL169-IN-B should be fed with a power limited voltage source between 8 and 36 Vdc and is not re-

quired a stabilisation due to the presence of an internal efficient stabiliser. The power supply is protected against polarity reversing

and is protected by a 750 mA internal SMT fuse. The current drawn depends on the power supply voltage and reaches it’s maximum

value during the transmission with the minimum supply voltage.  A value of 

450 mA

 may be used to choose an adequate supply unit.

a)

 

DL169-IN………………

b)

 

DL69-IN-B…………….

c)

 

DL169-IN-Y3………….

d)

 

RMO169-N-B-Y3……...

g)    DP03……………………

Radiomodem with RS232 and RS485 interfaces without box (open card version):

available with antenna lambda/4

 ANT119, ANT169L 

or vertical dipole

 ANT169DV

Radiomodem with RS232 and RS485 interfaces included in an extruded Aluminium box:

available with antenna lambda/4

 ANT119, ANT169L 

or vertical dipole

 ANT169DV

Radiomodem with RS232 and RS485 interfaces without box (open card version):

available with 3 elements Yagi antenna 

 WY 155 3N or ANT294

Radiomodem with RS232 and RS485 interfaces included in an extruded Aluminium box:

available with 3 elements Yagi antenna

  WY 155 3N or ANT294

Connection for guide DIN in extruded Aluminium

Содержание DL169-IN

Страница 1: ...he not received messages address reversing for the answer ECHO NAK to DTE at the end of repetitions address to DTE and so on These devices assembled with SMT components in the industrial temperature r...

Страница 2: ...ectronic switch As shown in the following Fig 1 the RS 232 interfaces utilises the connector pins from 2 to 8 while the RS 485 utilises the pins Nos 1 and 9 Radiomodem status with a bi colour LED norm...

Страница 3: ...nd electrically connected to the TNC ground simulates the ground plane and allows the utilisation of the 4 antennas ANT119 TNC shortened or ANT169L TNC full length For maximum efficiency in this case...

Страница 4: ...e communication network must be configured with these functions to allow the communication process because the improvement of the reliability of the communication is obtained lengthening the preamble...

Страница 5: ...Clock data in the packet A feature for specific application not available in the standard units LBT Listen Before Talk Before transmitting the module measure disturbing signal on the radio channel and...

Страница 6: ...the correct addressing of each packet The addressing is made by some additional bytes preceding the message in the following order One System Code Byte 1 255 One Flag byte with the bit having the foll...

Страница 7: ......

Страница 8: ......

Страница 9: ...1 1 JP6 HEAD6 2 JP1 JP2 RF BNC 1 JP5 100 H A7502HY 101M 1 L1 L3VEGW 1 LD1 L934RD 1 LD2 HMHAA280 1 OPT1 BC846B 5 Q1 Q2 Q4 Q6 Q8 BC856B 2 Q5 Q7 FDN5618P 1 Q3 2 7 1 1 R18 3 3 1 2 R13 R14 10 1 3 R37 R38 R...

Страница 10: ......

Страница 11: ......

Отзывы: