![Instrumentation GDD GRx8mini Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/instrumentation-gdd/grx8mini/grx8mini_instruction-manual_2070186140.webp)
Instrumentation GDD Inc. 2018-04-06
Page 140
Annex 4 – Example Dump File (.gdd format)
Version PPC: 0.4.2.42 Version Rx: 8.1.0.1 Rx SN: 1309
Project:
Windows: 20 Setting: Arith. Delay (ms): 240 Timing (ms): 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80
Mem Date
Hour
Array LineTx LineRx Dir
n
Tx1
Tx2
Rx1 Rx2
Contact Rho
1
06/11/2013 08:09:55 P-P
0.00
0.00
N-S
0.0 9999999.00 0.00 0.00 9999999.00 8.9
0.00
1
06/11/2013 08:09:55 P-P
0.00
0.00
N-S
0.0 9999999.00 0.00 0.00 9999999.00 16.0
0.00
1
06/11/2013 08:09:55 P-P
0.00
0.00
N-S
0.0 9999999.00 0.00 0.00 9999999.00 21.2
0.00
1
06/11/2013 08:09:55 P-P
0.00
0.00
N-S
0.0 9999999.00 0.00 0.00 9999999.00 24.2
0.00
Sp
SpMin SpMax Vp
ErrVp Sym(%) M
ErrM In
Time DC
Stack M01
…
0.4
0.4
0.4
125.112
0.001 100
7.947 0.009 1000.000 2000 50
10
7.974 …
0.5
0.4
0.7
250.336
0.001 100
7.945 0.002 1000.000 2000 50
10
7.954 …
0.7
0.7
0.8
375.726
0.002 100
7.947 0.002 1000.000 2000 50
10
7.961 …
-0.0
-0.1
0.9
500.038
0.002 100
7.945 0.000 1000.000 2000 50
10
7.952 …
First section - File header:
Version PPC:
Version of the Rx program on the PDA
Version Rx:
Version of the Rx firmware
Rx SN:
Serial number of the IP Receiver
Second section:
Project:
Name of your project
Third section:
Windows:
Number of windows (depending on the selected mode)
Setting:
Selected mode (Arith., Semi, Log., Cole, User)
Delay (ms):
Delay in ms before the first window (depending on the selected mode)
Timing (ms):
Timing of each window (depending on the selected mode)
•
The file is divided in 4 sections. The fourth one contains the data.
•
Sections 2 and 3 will be repeated within the same file following a parameter change.
•
Infinite values within Rho, TX1 and RX2 (in pole arrays) are represented by 9999999.00.
•
Values in section 4 are delimited by one or more spaces. Therefore, the import software
must treat consecutive delimiters as one.
•
Each line in section 4 has a fix number of entries. If less than 20 windows are defined for a
selected entry, the unused columns will be padded with 999.99
•
The example file is truncated on the right side omitting column M02 to M20
Содержание GRx8mini
Страница 7: ...Instrumentation GDD Inc 2018 04 06 Page 7 A B C D F G H I J K L M optional N O P Q E...
Страница 63: ...Instrumentation GDD Inc 2018 04 06 Page 63 2 If you want to verify the GPS time select Check GPS...
Страница 83: ...Instrumentation GDD Inc 2018 04 06 Page 83 4 The Allegro2 can now be accessed from the Windows File Explorer...
Страница 101: ...Instrumentation GDD Inc 2018 04 06 Page 101...
Страница 102: ...Instrumentation GDD Inc 2018 04 06 Page 102...
Страница 104: ...Instrumentation GDD Inc 2018 04 06 Page 104...
Страница 131: ...Instrumentation GDD Inc 2018 04 06 Page 131 3D Survey Pole Dipole 2 16...
Страница 138: ...Instrumentation GDD Inc 2018 04 06 Page 138 5 Your next setup on the field should be like this...