Service Menu
Function Block Number 12
12.
- CORRECTION FACTOR -
To view or alter the Rate Correction Factor press Enter when the RATE CORRECTION
FACTOR function block is displayed. The value can be altered when highlighted. Do not press
enter until required change is complete.
Rate Correction Factor is used with beltweighers to alter the flow rate reading by a fixed
percentage. This percentage can only be obtained from running the beltweigher into (or out of) a
weighsilo or measuring out into a truck or railcar and getting an accurate weight over time. The
Rate Correction factor is only applicable to the range of 50 to 200%. The Rate Correction Factor
should be set to 100% if no deadweight calibration test has been carried out.
The Beltweigher Rate reading is multiplied by the Rate Correction Factor/100.
Example:- Existing reading of 100kg/hr x RCF of 95% = 95kg/hr.
When the block is ready press Enter again. This will set the value and move on to the next
block, in this case LINEARISER.