PRECALIBRATE
11
C
- PRECALIBRATE -
EX VOLTAGE : MEASURE
EX VALUE : 10,0 VOLTS
LC mV/V : 2.000
DECIMAL : xxx.xxx
ZERO : 000.000
FS : 020.000
UNITS : kg
INCREMENT : 001
OVERRANGE : 024.000
FILTERBAND : 0000
FILTER TMIE : 10 secs
Or Set(from external excitation)
Key in excitation required
Loadcell sensitivity
Select Decimal Place
Low Range
Full Scale Range
or Tonne, Newton, lb...
001-100
Value
0000-9999 Counts, 9999 = no effect
1, 3, 5, 10 or 20 seconds
ZERO TRIM
12
C
C
PRECALIBRATE
SPAN TRIM
- PRECALIBRATE -
Service Menu
Function Block Number 11 (LCT or (08) Beltweigher or (08) Loss-in-Weight)
11.
- PRECALIBRATE -
SECURITY LEVEL
ZERO TRIM
SERVICE
SERVICE
Key
Key
Key
Key
Key
Key
Key
Page
35
Содержание 6004BW