SwitchLinc Timer Owner’s Manual
Page 17 of 23
Disabling/Enabling the One-Minute Warning
By default, SwitchLinc will flash the load when there is one minute left on the timer.
To disable the warning:
1) Tap the paddle bottom to turn the load off
The load will turn off
2) Tap the paddle top to turn the load back on
The load will turn on
3) Press & hold the paddle top until it beeps (10 seconds)
The SwitchLinc Status LED will begin blinking
4) Press & hold the paddle top until it beeps (10 seconds)
The SwitchLinc Status LED will continue blinking
5) Press & hold the paddle top until it beeps (10 seconds)
The SwitchLinc Status LED will stop blinking and turn on solid
To re-enable the warning, repeat steps 1-5.
Dimming/Brightening the Status LED
1) Tap the paddle bottom to turn the load off
The load will turn off
2) Press & hold the Set button on SwitchLinc until it beeps (3 seconds)
The SwitchLinc Status LED will begin blinking
3) Press & hold the Set button on SwitchLinc until it beeps (3 seconds)
The SwitchLinc Status LED will continue blinking
4) Press & hold the Set button on SwitchLinc until it beeps (3 seconds)
The SwitchLinc Status LED will stop blinking and turn on solid at its dimmest level
5) Use the paddle to brighten and dim the SwitchLinc Status LED to the desired brightness
•
Press & hold the paddle top to brighten
•
Press & hold the paddle bottom to dim
6) Once you have reached the desired brightness for the Status LED, tap the Set button on SwitchLinc
once
SwitchLinc will beep
Restoring Power to SwitchLinc Timer
SwitchLinc stores all of its settings, such as Links to other INSTEON devices, On-Levels/Ramp Rates,
etc., with non-volatile memory. Because settings are saved in this non-volatile memory, they will not be
lost in the event of a power failure.
In the event of a power loss SwitchLinc will automatically return the load to the brightness level it had
before power was interrupted.