On/Off Switch 

Yes 

Beeper Yes, 

configurable 

Battery Charging LED 

Yes, Embedded (shines red through case during charge) 

RF Range 

50’ Line-of-Sight 

Retains all settings without power 

Yes, all saved in Non-volatile EEPROM 

Mechanical 

Color  

White 

Plastic 

UV Stabilized ABS 

Dimensions 

2.6" H x 1.3" W x 0.39" D 

Weight 1 

Oz. 

Button Style 

Plastic Paddles over Contact Switches 

Wall Mount 

Tabletop Stand 

Optional Hardware 

Visor Clip 

Operating Environment 

Indoors, 32°F to 104°F, up to 85% relative humidity 

Electrical 

Battery type 

3.7 VDC Lithium Polymer, Rechargeable, non-replaceable 

Battery life (between charges) 

9-12 months under standard usage 

Battery Re-charging cycles 

> 500 recharging cycles 

Recharging jack 

Standard, Micro-USB, 5VDC 

Recharging time 

1 hour 

Troubleshooting 

Problem 

Possible Cause 

Solution 

RemoteLinc 2 may be out of range of 
nearest dual-band INSTEON device 
(hopper)  

Try moving an access point or other dual-band 
plug-in module closer to RemoteLinc 2 

The INSTEON signal may not be 
getting to the “vicinity” of Responder 

Make sure phases are bridged, add additional 
INSTEON devices and/or move around existing 
INSTEON devices 

Large appliances, such as refrigerators 
or air conditioners, may be producing 
electrical noise on the power line 

RemoteLinc 2 won’t add a 
scene responder  

Other electrical devices, such as 
computers, televisions, or power strips, 
may be absorbing the INSTEON signal 

Install a power line noise filter (e.g., #1626-10) to 
filter electrical noise and minimize signal attenuation

RemoteLinc 2 will not turn 
a Responder On (it may 
turn it off)  

Ramp Rate may be Extremely Slow 
                              Or 
Responder may be Linked at OFF 
 

Re-link to Responder with fast Ramp Rate  

                                                                                                                   Page 13 of 15                                                                           2444A2xx4 Rev: 10/24/2011 10:50 AM 

 

Содержание RemoteLinc 2

Страница 1: ...RemoteLinc 2 INSTEON Remote Control Keypad 4 Scene 2444A2xx4 Owners Manual Page 1 of 15 2444A2xx4 Rev 10 24 2011 10 50 AM...

Страница 2: ...uck Button 8 Advanced Features 8 Add Multiple Responders to a Scene Multi Link 8 Remove Multiple Responders from a Scene Multi Unlink 8 Change Button Scene Configuration e g Change to 8 Button Mode 9...

Страница 3: ...nted on wall with no trim plate wireless keypad Mounted on wall in a single gang Decorator trim plate wireless keypad built in look Mounted on wall in a multi gang Decorator trim plate add to the numb...

Страница 4: ...e Stuck Button Mode saves battery life by going to sleep if button stuck down Beeper for setup ease Recharges with standard USB charger with via Micro USB Plug 5VDC 9 12 month battery life based on av...

Страница 5: ...nt your RemoteLinc 2 anywhere Gang two or more together for more control Can be installed adjacent to existing wired in switches RemoteLinc 2 can easily be removed for portability or recharging Use wi...

Страница 6: ...ast Off Add RemoteLinc 2 Button to a Scene as a Controller Follow the steps below to control a scene one or more INSTEON devices 1 Tap the RemoteLinc 2 scene button of choice on or off buttons will bo...

Страница 7: ...on Tap Press hold Double tap On Right Turn scene on Brighten scene members until released Turn scene members full bright instantly Off Left v Turn scene off Dim scene members until released Turn scene...

Страница 8: ...s the RemoteLinc will automatically stop transmitting to preserve battery life The RemoteLinc 2 will automatically turn back on when the button that was depressed is no longer being pressed Advanced F...

Страница 9: ...2nd time for 3 seconds until you hear a beep RemoteLinc 2 s LED will blink RED 3 Press Hold Set Button a 3rd time for 3 seconds until you hear a beep RemoteLinc 2 s LED will blink GREEN 4 Press Hold...

Страница 10: ...its LED turns off returns to Ready Mode Turn Beeper On During Usage or Back Off 1 Press Hold Set Button for 3 seconds until you hear a beep RemoteLinc 2 s LED will blink GREEN 2 Press Hold Set Button...

Страница 11: ...formation LED State Meaning Add Responder Setup Mode or Blinking Green slowly LED on off Setup Mode Blinking Red slowly Remove Responder Setup Mode Multi Add Responder Setup Mode or Double Blinking Gr...

Страница 12: ...nding Warranty 1 Year Limited INSTEON Scenes 4 default configurable to 8 Scene Configurations 4 On Off default 8 Toggle or 8 Always On Maximum scene Links 400 On Off Begin Brightening Begin Dimming En...

Страница 13: ...ing Problem Possible Cause Solution RemoteLinc 2 may be out of range of nearest dual band INSTEON device hopper Try moving an access point or other dual band plug in module closer to RemoteLinc 2 The...

Страница 14: ...fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Страница 15: ...rms of the above warranty and disclaimer Home automation devices have the risk of failure to operate incorrect operation or electrical or mechanical tampering For optimal use manually verify the devic...

Отзывы: