Environmental (Information
On Disposal For Users
Of Waste Electrical &
Electronic Equipment)
The “crossed out wheelie bin” symbol on
this product means that discarded electrical
and electronic products should not be mixed
with general waste. Disposing of the product
correctly will help to save valuable resources
and prevent any potential negative effects
on human health and the environment which
could otherwise arise from inappropriate
waste handling. For proper treatment,
recovery and recycling of end-of-life products,
please contact your dealer or supplier for further
information, or local authority for details of your
nearest designated collection point.
Delivery Checklist
Before starting installation, check that you have
the following parts;
• Catering Water Boiler
• Drip-tray
• Drip-tray fitting kit
• White water inlet hose (3/4”BSP connection)
• User instructions
Technical Specification
Model
1501F 3001F
Width
mm
252
310
Depth
mm
518
518
Height
mm
610
618
Power Rating
KW
3.0
3.0
Weight (Empty)
KG
13.5
15.5
Weight (Full)
KG
28
36
Water Inlet Pressure: Bar
2 to 7 2 to 7
Installation
The boiler must be installed on a level work
surface with sufficient strength to support
its weight. Ensure all vents are unobstructed.
Locate in an area where there is adequate space
to use the boiler safely (e.g. free from risk of
congestion and tripping hazards).
Connection to Mains Water Supply:
Connect the WRAS approved water filling hose
(3/4”BSP) to the inlet connection point on the
back of the boiler and the other end to the mains
water supply, via an accessible isolating tap with
a ¾”BSP thread*.
IMPORTANT:
If micro-bore pipe is used instead
of the inlet hose supplied, the size must be
minimum OD 3/8”(10mm).
The water supply must have a pressure not
exceeding 7bar (96psi), and no lower than 2bar
(20psi) NOTE: If your water pressure exceeds
7bar, fit a suitable pressure reduction valve.
We regret that Instanta cannot be held
responsible for any machine malfunctions if
the water pressure exceeds that stated. If in
doubt, consult your water supply company.
*To meet WRAS installation requirements, an
approved single-check valve providing back-
flow prevention protection, should be fitted
at the point of connection between the water
supply and the appliances.
Electrical Connection:
The boiler must be Earthed.
Your machine is supplied with a standard 13amp
bonded plug with a 13amp fuse.
Overflow:
The drip-tray has a limited capacity and is
designed to handle small spillages and drips.
Wherever possible, we strongly recommend
that it is connected to a permanent waste outlet
using the fitting kit provided.
If preferred, and as an alternative, the
overflow can be connected from the back of
the machine using an optional rear-overflow
kit (Pt. No: ROFK1) available from Instanta
Spares Department (01704 502905).
IMPORTANT:
Whichever overflow connection is
chosen, the diameter of the pipe used must be
no less than 15mm.
Failure to connect the overflow-outlet to a
permanent waste of drain, could lead to property
damage from flooding.
If in all circumstances, it is absolutely not
possible to direct the boiler overflow-outlet to
3