background image

3.  Align a flat screw-driver or similar with the tab 

on the filter and gently push.

4.  With one tab loosened, pull the filter cap off 

the old cartridge.

5.  Align the shape on the inside of the filter cap 

(highlighted above) with the shape on the end 

of the new filter and push the two together 

until it clicks firmly in place.

6.  Remove protective cap from the top of the 

new cartridge and ensure the two rubber 

seals are in place.

7.  Insert new cartridge and turn until it locates. 

Install with a quarter-turn to the right 

until cartridge comes to a complete stop 

(Inlet water will automatically turn on).

8.  Switch boiler back on and allow to fill  

(15 minutes).

5

Содержание 3001F

Страница 1: ...Auto Fill Catering Water Boiler With Integrated Multi Filter Installation And User Instructions INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB31 ISS 0...

Страница 2: ...wing Health Safety at Work Act IEE Regulations Local national Building Regulations BS Codes of practice Water Supply Regulations All personnel should be provided with sufficient training in the safe u...

Страница 3: ...ction point on the back of the boiler and the other end to the mains water supply via an accessible isolating tap with a BSP thread IMPORTANT If micro bore pipe is used instead of the inlet hose suppl...

Страница 4: ...st 15 minutes before starting to use Drain off approximately 10 litres of water to flush the new filter cartridge through The boiler is now ready for use Regular Daily Use Switch boiler on and wait fo...

Страница 5: ...e shape on the end of the new filter and push the two together until it clicks firmly in place 6 Remove protective cap from the top of the new cartridge and ensure the two rubber seals are in place 7...

Страница 6: ...hine off Press hold on off button for approximately 12 seconds until red screen shows PR in top right corner then release button Temperature setting is displayed Press hold button long push for approx...

Страница 7: ...amounts of cold water to ensure all traces of de scaler are removed before using the boiler again Replace evaporation plates tank lid and outer lid Draw off tap The draw off tap components are subjec...