background image

9.  Drain-off approximately 10 litres of water.

10.  TO RESET FILTER MONITOR: …Press and 

hold “On/Off” button, screen will go blank 

but continue to hold, until “READY” message 

is displayed on a red screen.

The boiler is now ready for use.

Adjusting Filter Monitor 
(Optional):

The filter monitor is factory-set to “medium” 

(default) which is suitable for most parts of the 

UK with average or medium water hardness.
Hard and Soft Water: The effectiveness of 

the filter will be reduced in hard water areas 

(and should be replaced more frequently), 

or extended in soft water areas where scale 

is less of a problem.
If in doubt as to the hardness of water supplied 

in your area, consult your local water authority or 

Instanta Technical Support.

The filter monitor on the boiler can be changed 

from the default “medium” setting to “hard” or 

“soft” setting as follows;
Replace the filter cartridge (as steps 1 to 9 

“AQ35 Filter Replacement” above). Then;
•  Turn machine off.
•  Press & hold “on/off” button (for 

approximately 12 seconds) until red screen 

shows “PR” in top-right corner, then release 

button. Temperature setting is displayed.

•  Press & hold button (long push) 

for approximately 5 seconds until 

screen changes to show “medium” 

(default filter setting).

•  Press button (short push) to scroll 

between the different filter settings; 

SOFT 

MEDIUM 

HARD 

EMPTY FILTER SYMBOL (No Filter monitor).

•  With the required filter setting selected, 

Press & hold button (long push) for 

4 seconds to save.

•  Press & hold button (long push) for 

approximately 6 seconds until display 

goes blank.

•  Turn machine back on again.
•  TO RE-SET & CONFIRM NEW SETTINGS; 

…Press & hold button, screen will go 

blank but continue to hold, until “READY” 

message is displayed on a red screen 

(See; Step 10 above).

Cleaning

•  Clean the external surfaces of the boiler 

regularly to maintain good hygiene

•  Empty the front drip-tray regularly 
•  Wipe external surfaces of the boiler with a 

damp cloth. Do not use abrasive materials 

on the outer surfaces.

•  Wipe the draw-off tap each day to keep 

clean and also prevent lime-scale deposits 

from building up around the tap-outlet.

6

Содержание 3001F

Страница 1: ...Auto Fill Catering Water Boiler With Integrated Multi Filter Installation And User Instructions INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB31 ISS 0...

Страница 2: ...wing Health Safety at Work Act IEE Regulations Local national Building Regulations BS Codes of practice Water Supply Regulations All personnel should be provided with sufficient training in the safe u...

Страница 3: ...ction point on the back of the boiler and the other end to the mains water supply via an accessible isolating tap with a BSP thread IMPORTANT If micro bore pipe is used instead of the inlet hose suppl...

Страница 4: ...st 15 minutes before starting to use Drain off approximately 10 litres of water to flush the new filter cartridge through The boiler is now ready for use Regular Daily Use Switch boiler on and wait fo...

Страница 5: ...e shape on the end of the new filter and push the two together until it clicks firmly in place 6 Remove protective cap from the top of the new cartridge and ensure the two rubber seals are in place 7...

Страница 6: ...hine off Press hold on off button for approximately 12 seconds until red screen shows PR in top right corner then release button Temperature setting is displayed Press hold button long push for approx...

Страница 7: ...amounts of cold water to ensure all traces of de scaler are removed before using the boiler again Replace evaporation plates tank lid and outer lid Draw off tap The draw off tap components are subjec...

Страница 8: ...as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right hand side of machine This is essential Guarante...

Отзывы: