25
Hardware Options Installation
Notes:
●
It is required to coat thermal grease evenly onto the contact position between CPU
heatsink and CPU.
●
The pins of the processor socket are easily damaged. If any pins are damaged, you may
need to replace the motherboard.
6.2 Memory Option
IMPORTANT:
This server does not support mixing DIMMs. Attempting to mix the DIMMs of two different
types may cause the server stops running during initialization.
All DIMMs installed in the server must be the same type.
●
DIMM slot layout is as shown in the following figure:
Figure 6-4
Step 1: Open the lock tabs on both ends of the DIMM slot.
Step 2: Align the bottom key with the receptive point on the slot, press both ends of the
DIMM with your thumbs. Insert the DIMM into the slot completely, and the lock tabs will
automatically secure the DIMM, locking it into place.