128
Note:
Hot-plugging HDD allows users to take out or replace the HDD without system
shutdown and power off, which improves the system disaster recovery capability, scalability
and flexibility. It only means the hot-plug HDD can be plugged in and out online without
damage, and the following two items need to be noticed:
①
Depending on the RAID level,
hot plugging the HDD in the RAID will cause RAID degradation or failure. When installing
a new HDD, different RAID cards have different policies, you may need to login to the
RAID card management interface for recovery.
②
Remove the HDD until the HDD motor
stops completely, to prevent damage to the motor. For the operations on the RAID card
management interface, please refer to Inspur technical website: www.4008600011.com
.
6) Chassis fans make excessive noise
Suggestions:
a.
Firstly check whether the chassis fans operate at a high speed caused by the over-
temperature chassis.
b.
If the chassis has a high temperature, check the temperature of server room, if it is
excessively high, open the air conditioner to cool the room.
c.
If the server room’s temperature is normal, check whether the front panel or chassis
interior is jammed with dust, or the air inlet is blocked. It needs to improve the server
room’s environment, to avoid server over-temperature running because of too much dust.
d.
Check whether the server runs under high load.
e.
If above operations could not resolve the problem, please contact Inspur customer service.
7) There is alarm sound during startup
Suggestions:
Firstly identify the source of alarm sound:
a.
If the alarm sound comes from the power supply, check the power LED’s status. If the
power LED is abnormal, refer to item 3) to handle it.
b.
If the alarm sound comes from the chassis interior, open the chassis to identify the
specific source.
c.
If the alarm sound comes from the RAID card, check the HDD LED status or login to the
RAID management interface to check the HDD status. For the operations about the RAID
management interface, please refer to Inspur technical website: www.4008600011.com
.
d.
If above operations could not resolve the problem, please contact Inspur customer
Содержание NF5266M5
Страница 1: ...Inspur Server User Manual NF5266M5 ...
Страница 109: ...BMC Settings 103 Figure 9 5 Figure 9 6 Figure 9 7 ...
Страница 113: ...BMC Settings 107 Figure 9 15 Figure 9 16 Figure 9 17 Figure 9 18 ...
Страница 115: ...BMC Settings 109 Figure 9 20 Figure 9 21 Figure 9 22 ...
Страница 116: ...110 Figure 9 23 Figure 9 24 ...
Страница 118: ...112 Figure 9 27 Figure 9 28 ...
Страница 120: ...114 Figure 9 32 Figure 9 33 Figure 9 34 Figure 9 35 ...
Страница 122: ...116 Figure 9 37 Figure 9 38 ...
Страница 123: ...BMC Settings 117 Figure 9 39 Figure 9 40 ...