5.5 Installing the Server into the Rack
CAUTION:
Always plan the rack installation so that the heaviest item is on the bottom of
the rack. Install the heaviest item first, and continue to populate the rack from the bottom
to the top.
1.
Install the server and cable management arm into the rack. For more information, see
the installation instructions attached with the 2U Quick Deploy Rail System.
2.
Connect peripheral devices to the server. For connector identification information, see
“Rear panel components” in this guide.
WARNING:
To reduce the risk of electric shock, fire, or damage to the equipment, do not
plug telephone or telecommunications connectors into RJ-45 connectors.
3.
Connect the power cord to the rear of the server.
4.
Connect the power cord to the AC power source.
WARNING:
To reduce the risk of electric shock or damage to the equipment:
• Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at
all times.
• Unplug the power cord from the power supply to disconnect power to the equipment.
• Do not route the power cord where it can be walked on or pinched by items placed
against it. Pay particular attention to the plug, electrical outlet, and the point where the
cord extends from the server.
5.6 Installing the Operating System
To operate properly, the server must have a supported operating system installed. For the
latest information on supported operating systems, refer to the Inspur website (http://
www.inspur.com/eportal/ui?pageId=444443).
Содержание NF5266M5
Страница 1: ...Inspur Server User Manual NF5266M5 ...
Страница 109: ...BMC Settings 103 Figure 9 5 Figure 9 6 Figure 9 7 ...
Страница 113: ...BMC Settings 107 Figure 9 15 Figure 9 16 Figure 9 17 Figure 9 18 ...
Страница 115: ...BMC Settings 109 Figure 9 20 Figure 9 21 Figure 9 22 ...
Страница 116: ...110 Figure 9 23 Figure 9 24 ...
Страница 118: ...112 Figure 9 27 Figure 9 28 ...
Страница 120: ...114 Figure 9 32 Figure 9 33 Figure 9 34 Figure 9 35 ...
Страница 122: ...116 Figure 9 37 Figure 9 38 ...
Страница 123: ...BMC Settings 117 Figure 9 39 Figure 9 40 ...