insize ISP-A5000 Скачать руководство пользователя страница 3

2

Cross Hair measurement
Automatic Edge Detector measurement (ISP-A1000E)

Counter clock wise direction

Clock wise direction

Degree Decimal mode (90.0000°)

Degree Minutes Seconds display mode (90°.00'.00'')

Contrast level increase

Contrast level decrease

Select

Exit

Open

Yes

No
On (Disable)

Off (Enable)

Auto edge detection setup (ISP-A1000E)

Engineering Setup

View Results

Delete Selected Result

Delete all result

 A

Program menu
Tolerance option

Print Result Buffer

Repeat Function

C e n t r e - N e a r - F a r  K e y.  Vi s i b l e  o n l y  w h e n  r e s u l t  i s 
constructed Distance Either from two lines or two circles.

Center Distance between two circles or lines

Nearest Distance between two circles or lines

Farthest Distance between two circles or lines

25

The surfaces of optical parts should be kept clean. They should not 
be touched with hands. If any dirt, oil fleck or dust are found on the 
surfaces,  they  should  be  removed  with  soft  brushes,  or  they  should 
be  removed  with  clean  linen  or  lens  paper  soaked  in  methyl  benzol 
or in a mixture of alcohol and ether. Try to rub the optical surfaces as 
less as possible.
The  instrument  should  not  be  operated  with  a  big  force.  All  bare 
metal  surfaces  of  the  instrument  and  the  accessories  should  be 
wiped clean and coated with protection grease after operation. 
When work-piece with larger diameter is to be measured, take down 
objectives 50x and 100x and place them into the accessory box.
Objectives,  guides  and  condenser  have  higher  precision.  They 
should not be dismantled optionally. If it is necessary, they should be 
sent to the specialized factories for repair.

2

3

4

5

Содержание ISP-A5000

Страница 1: ...www insize com ISP A5000 A5000E PROFILE PROJECTOR OPERATION MANUAL V0 MN ISP A5000 A5000E E MN ISP A5000 A5000E E...

Страница 2: ...tility Keys 8 Numeric Function Keys 9 Coordinate And Unit Switch Buttons 10 Axis Reset Keys Point Feature key Line Feature Key Circle feature key Distance Feature Key Angle Feature Key Skew Feature Ke...

Страница 3: ...tween two circles or lines 25 The surfaces of optical parts should be kept clean They should not be touched with hands If any dirt oil fleck or dust are found on the surfaces they should be removed wi...

Страница 4: ...hould be located If the point is located outside the zone tolerance fails Press key then enter the nominal values for X and Y co ordinates Also enter the values for each nominal value Limits allow the...

Страница 5: ...esults we must do the cross calibration process for every magnifications If we don t execute cross cal and if we probe a circle by cross hair and by edge detector in both cases we will get diameter eq...

Страница 6: ...his sets the gain of the amplifier The gain depends on the magnification and the light source Adjust this such that the Screen intensity on light region displays counts above 3000 counts to 4000 In ca...

Страница 7: ...to user defined segments The error in each segment is compensated with a single correction factor Each correction point is measured with respect to the starting point This starting point is usually se...

Страница 8: ...the next segment by pressing Next Calibration Edit Procedure When all the segments are complete press Enter key 20 Edge Detector For ISP A1000E Optical Edge detection can be used with DRO to increase...

Страница 9: ...nd measured X and Y coordinates from the standard during the setup process NLEC requires a repeatable machine zero defined on startup 3 The changes will get saved in the memory and are applied The use...

Страница 10: ...ual softkey Display value will show counts of respective rotation User will enter angle of rotation in seconds Now user can calculate calibration factor by pressing calc softkey After calibration pres...

Страница 11: ...t on the line and match cross hair on it Press key A Now in similar manner probe sufficient points to form a best fit line And then press key A Circle Measurement A circle can be measured by selecting...

Страница 12: ...al view of results will be displayed Use up down arrow keys to move next or previous results one by one or press key to recall particular result 9 Exit from result buffer view Visible only if result i...

Страница 13: ...eature measurement Also it automatically detects which geometrical shape has been probed This feature can be activated once or repeat 8 15 Skewing the job is also possible from constructed features Th...

Страница 14: ...Note As shown in the above figure the part must be placed within 45 degrees of the machine s co ordinate system Procedure for skewing the job Press key Following screen will be displayed Press key to...

Отзывы: