background image

12

 ④

 

Delete the selected data

The range of data to be deleted should be set up under this menu. 
The selected data will be deleted by pressing button “OK”. It will be 
aborted by pressing button “RETURN”.

Fig 4-21

 

 

 ⑤

 Delete all data

The prompt window will be pushed out under this menu. All data 
will be deleted by selection of “YES”, and this operation will be  
aborted by selection of “NO”.

Fig 4-22

 5) Print setting

 The data saved in the durometer can be printed by the thermal 
 printer.

 

Auto-print ON/OFF setting

The durometer will send the data to the thermal print after the 
finishing of one statistic group under this function is set as on. 
Otherwise, the durometer will not send data to the thermal print.

Fig 4-23

 

 

5

Fig 4-2

Fig 4-3

Fig 4-4

Содержание ISH-DSD

Страница 1: ...ISH DSD www insize com OPERATION MANUAL DIGITAL SHORE DUROMETER MN ISH DSD E V0...

Страница 2: ......

Страница 3: ...foot surface The value of L indicates the value of Shore Hardness of the sample Larger the value of L smaller the Shore Hardness Conversely smaller the value of the L sample s Larger the sample s Shor...

Страница 4: ...n flooring bowing Especially for on site hardness measurement of rubber and plastic products 15 2 Print report There are several print modes built in the durometer You can select by yourself 3 Auto pr...

Страница 5: ...Low voltage alarming and recharge The durometer will be recharged by the packaged charger The durometer will not be auto power on during recharging The charging status will show on the measuring inter...

Страница 6: ...e current times Measure mode Indicating the current measure mode AVE Average measure mode Max Maximum value measure mode MAX AVE Maximum average value measure mode 2 Menu 7 6 5 4 3 2 1 Fig 4 1 Hardnes...

Страница 7: ...r this menu All data will be deleted by selection of YES and this operation will be aborted by selection of NO Fig 4 22 5 Print setting The data saved in the durometer can be printed by the thermal pr...

Страница 8: ...ssing button UP The measure date time sample code of the current data can be shown pressing button OK 6 1 Calibration Pressing button OK to enter the menu select Calibration press button The durometer...

Страница 9: ...tically The average value of maximum value of every measuring will be calculated and this value will be taken as the last result Measure times setting The statistic times can be set under this menu Th...

Страница 10: ...l be button RETURN be aborted by press 8 Tolerance limit setting Under this menu the tolerance limit can be set When the measuring data is exceed the setting value the icon of will be showed on the LC...