7.3.3.3. Output Timing Tab
Figure 7-25 shows a GUI window of the Output Timing test. This tab operates with the measurement
of Output Timing.
Figure 7-27 A GUI window of the Output Timing
Steps:
1. Enter an appropriate SD side block address in the
“
Block Address
”
by hexadecimal.
2. Enter an appropriate block count in the
“
Block Count
”
by hexadecimal.
3. Enter an appropriate value in the
“
Loop Count
”
(number of test trials) by hexadecimal.
4. Select
“
VDD
”
.
5. Select a slot.
6. Select a data pattern. (refer to section 7.2.3.5.)
7. Click the
Run
button to start the Output Timing check operation.
When these operations are running, the status monitoring and the process bar will become
active.
8. To stop a test, click the
Stop
button.