8.9. DISASSEMBLY AND ASSEMBLY OF THE SINGLE MECHANICAL SEAL
8.9.1. Disassembly for the M-226 and M-440 blender
1. Disassemble the housing and impeller as shown in chapters
8.8.1. Disassembly of the housing
and impeller for the M-226 blender
or
8.8.2. Disassembly of the housing and impeller for the
.
2.
Remove the rotating part of the mechanical seal (08).
3.
Remove the blender cover (03).
4.
Remove the fixed part of the mechanical seal (08) which is housing inside the cover blender (03).
3.
Slide the rotating part of the mechanical seal (08) through the shaft (05) until the stop.
02.002.32.0013
02.002.32.0014
8.9.2. Assembly for the M-226 and M-440 blender
1.
Mount the blender cover (03). In the M-226 model, mount it over the lantern and in the M-440
model mount it over the bearing support.
2.
Place the fixed of the mechanical seal (08) in the housing of the cover (03) taking into account
the shaft pivot. Check that the assembly measure is that which is detailed in the following table:
Model
Seal diameter
A (mm)
M-226
1’’
26
M-440
1½
31
ATTENTION
When assembly the new single mechanical seal, take care to assemble the pieces and
the seals lubricated with soapy water to facilitate their slide, as the fixed part as of the
rotating part.
8.10. DISASSEMBLY AND ASSEMBLY OF THE COOLED MECHANICAL SEAL
8.10.1. Disassembly cooled mechanical seal for the M-226 blender
1.
Remove the rotating part of the mechanical seal (08).
2.
Remove the blender cover (03A).
3.
Remove the fixed parts of the mechanical seals (08) which are housing inside the blender cover
(03A).
4.
Disassemble the pins of the rotating part of the bottom mechanical seal (08) and slide it through
the shaft (05).
8.10.2. Disassembly cooled mechanical seal for the M-440 blender
1.
Remove the rotating part of the mechanical seal (08).
2.
Remove the blender cover (03A) together with the cap (10).
3.
Remove the fixed parts of the mechanical seals (08) which are housing inside the blender cover
(03A).
Maintenance
19
INOXPA S.A.U.
02.002.30.02EN · (0) 2021/04