— 13 —
AC (MAINS) POWER
Mains Voltage
Selector
Unless specifically ordered for export shipment, the 531N is set
at the factory for operation from 115V, 50/60Hz AC mains.
This can be confirmed by checking the designation next to the
fuseholder on the rear panel. The
inappropriate
voltage and
fuse value will have been crossed out at the factory with an in-
delible felt marker.
To change the mains voltage,
first
disconnect the AC power cord
and then remove the top cover of the unit. A clearly marked
slide switch is next to the AC mains connector on the circuit
board. Use a small screwdriver to set the switch for
115VAC
or
230VAC
operation.
Be sure to install the appropriate fuse as listed next to the
fuseholder. You can remove the factory strikethrough with sol-
vent and then cross out the inappropriate marking with an in-
delible felt pen.
Mains Fuse
It is important to install the appropriate fuse as noted on the
rear panel next to the fuseholder: 1/4A for 115V mains, 1/8A
for 230V operation. Fuses are GMA 5mm X 20mm ‘fast blow.’
Power Cord
The detachable IEC-type power cord supplied with the 531N is
fitted with a North-American-standard male plug. If you need
to replace the mains plug with another, you will find that the
individual cord conductors are color-coded in one of two ways.
US standards specify black for AC ‘hot,’ white for AC neutral
(return) and green for earth ground. European CEE standards
specify brown for AC ‘hot,’ blue for AC neutral and green with
a yellow stripe for earth ground. Please keep these straight.
RADIO FREQUENCY INTERFERENCE (RFI)
Location
Although it is expected that the 531N will be co-located with
FM transmission equipment, do practice care and common
sense in locating the unit away from
abnormally
high RF fields.
Ground Loops
Because the inputs and the outputs of the Model 531N are ref-
erenced to chassis ground, a mains frequency or RF ground
loop could be formed between cable shield grounds and the AC
power cord ground. A ‘ground-lifting’ AC adapter may well
remedy such a situation, though the chassis somehow must be
returned to local earth ground for safety considerations.
RF INPUTS
Antenna Input
and Antennas
The 531N antenna input is a US-standard 75-ohm F connector.
Inexpensive, ready-made cables of various lengths are common