53
Function
code
Parameter Name
Setting Range
Unit
Default
Commission
F9-39
Frequency upon 1st
fault
-
-
-
F9-40
Current upon 1st fault
-
-
-
F9-41
Bus voltage upon 3rd
fault
-
-
-
F9-42
DI status upon 1st fault -
-
-
F9-43
Output terminal status
upon 1st fault
-
-
-
F9-44
Frequency upon 1st
fault
-
-
-
F9-47
Fault protection action
selection 1
00000 to 22222
N.A
0000
F9-48
Fault protection action
selection 2
00000 to 11111
N.A
0000
F9-49
Fault protection action
selection 3
00000 to 22222
N.A
0000
F9-54
Frequency selection
for continuing to run
upon fault
0 to 4
N.A
0
F9-55
Backup frequency
upon abnormality
0.0 to 100.0 (maximum frequency)
Hz
100.0
F9-59
Action selection at
instantaneous power
failure
0: Invalid
1: Decelerate
2: Decelerate to stop
N.A
0
F9-60
Action pause judging
voltage at
instantaneous power
failure
80.0 to 100.0
%
90.0
F9-61
Voltage rally judging
time at instantaneous
power failure
0.00 to 100.00
s
0.50
F9-62
Action judging voltage
at instantaneous
power failure
60.0 to 100.0 (standard bus voltage)
%
80.0
F9-63
Protection upon load
becoming 0
0: Disabled
1: Enabled
N.A
0