Group F3: V/F Control
Function
code
Parameter Name
Setting Range
Unit
Default
Commission
F3-00
V/F curve setting
0 to 9
N.A
0
F3-01
Torque boost
0.0 to 30.0
%
Model
dependent
F3-02
Cut-off frequency of
torque boost
0.00 to maximum output frequency
Hz
50.00
F3-03
Multi-point V/F
frequency 1 (F1)
0.00 to F3-05
Hz
0.00
F3-04
Multi-point V/F voltage
1 (V1)
0.0 to 100.0
%
0.0
F3-05
Multi-point V/F
frequency 2 (F2)
F3-03 to F3-07
Hz
0.00
F3-06
Multi-point V/F voltage
2 (V2)
0.0 to 100.0
%
0.0
F3-07
Multi-point V/F
frequency 3 (F3)
F3-05 to rated motor frequency (F1-04)
Hz
0.00
F3-08
Multi-point V/F voltage
3 (V3)
0.0 to 100.0
%
0.0
F3-09
V/F slip compensation
gain
0 to 200.0
%
0.0
F3-10
V/F over-excitation
gain
0 to 200
%
64
F3-11
V/F oscillation
suppression gain
0 to100
%
Model
dependent
F3-13
Voltage source for V/F
separation
0 to 8
N.A
0
F3-14
Voltage digital setting
for V/F separation
0 to rated motor voltage
V
0
F3-15
Voltage rise time of
V/F separation
0.0 to 1000.0
s