4
MECHANICAL INSTALLATION
4.1
Compatibility
4.1.1
Hardware Compatibility
4.1.1.1
Machine Mounting
The NV200 is not retro-fittable in place of any older Innovative Technology validator
however it’s footprint is comparable to other high end casino validators, some re
-
work may still be required to use the NV200 in place of a different validator.
4.1.1.2
Machine Interfacing
By design the NV200 family is pin to pin across the range, should there be any
questions regarding the pin-outs see
section 2.4.1
. If integrating different modules,
a change in the harnessing may be required, details of recommended harness
configurations can be found in section
5.2.3
.
4.1.1.3
Power Supply
As outlined above in
Section 3.4
it is vital that the NV200 is connected to a power
supply capable of meeting the current requirements as an underpowered PSU can
cause events such as note rejects or missing credits. If the NV200 is used as a fitting
replacement for an older product its recommended to test the power supply
ensuring it meets the requirements of the NV200; please bear in mind the aging of
the capacitors
in the power supply could affect it’s
ability to supply peak current
loads. Refer to
Section 7.4
for full power requirement details.
Caution!
An insufficient power supply can cause erratic performance!
4.1.2
Software Compatibility
4.1.2.1
Interface Protocols
When using the NV200 as a fitting replacement for an older model or product some
events such like credits may be given at a different time, due to modified firmware
routines. This may cause missing events such like credits in certain host machines
where timeouts are tightly defined for the older model or product. Please contact the
machine manufacturer for full compatibility.
Caution!
Timing issues may cause missing events!
4.1.2.2
Re-programming
For re-programming the NV200 always use the latest version of Validator Manager
which is available for download on our website. Older versions may not fully support
the NV200. For further details on Re-programming the NV200 refer to
6.3
.
Caution!
Older versions of Validator Manager may not completely support the NV200!