MU8002-012ENEU rev03
11
-4-
MAINTENANCE, SERVICING, STORAGE
a) Before each use, the user must read and understand the Manufacturer’s Instruction and
safety manual. Ensure that the markings are visible at all times.
b) Before each use, carefully inspect the XTIRPA system and all components and parts there-
of. Any defective parts or components could result in serious injury or death.
c) The standards require a regular inspection program for any entrance/recuperation equip-
ment in closed space, as well as keeping the documented results of these inspections up to
date. Use the maintenance and inspection logs included in this Instruction and safety manual
to document the results.
d) It is recommended that the anchoring device be marked with the most recent or next inspec-
tion date.
e) Remove the XTIRPA system from service if a problem or an unsafe or defective condition
is found during the inspection. Return to an authorized service center or the manufacturer
for service.
f) Replacement components and parts and additional maintenance and servicing procedures
must be completed by an authorized service center which has been approved by the manu-
facturer, or by the manufacturer itself.
g) If leveling screwing pads do not move freely, they must be lubricated with a light machine oil.
h) Establish a monthly inspection which should be done by a competent person (person who
is familiar, has been trained and has read and fully understands this Instruction and safety
manual), other than the user.
WARNING
: A periodic inspection should be performed at least once every twelve months.
i) Periodically clean the exterior of the davit arm and base, using water and mild detergent.
Clean labels as required.
j) Store the XTIRPA system in a clean and dry environment, out of direct sunlight. Avoid areas
with chemical or toxic vapors, substances or environments. Do not immerse or leave in direct
contact with water, as corrosion and rust may occur. Inspect the XTIRPA system after any
period of extended storage and at least once a month.
k) The XTIRPA system and its components was designed for 10 years of continuous service.
The life expectancy of the XTIRPA system and its components will be determined after
periodic and monthly inspections that will determine whether or not the product may remain
in service.
l) All components and parts of the XTIRPA system should be stored in separate bags to facil-
itate transport and handling.