MU8012-002ANG Rev2 2016
P. 7
-4-
MAINTENANCE, SERVICING, STORAGE
a) Before each use, the user must read and understand the Manufacturer’s Instruction and safety manual.
Ensure that the markings are visible at all times.
b) Before each use, carefully inspect the
XTIRPA
System and all components and parts thereof. Any
defective parts or components could result in serious injury or death.
c) ANSI, OSHA, CSA and CE require a regular inspection program for all confined space entry/retrieval
equipment and to maintain documented results of these inspections. Use the maintenance and inspection
logs included in this instruction and safety manual to document the results.
d) It is recommended that the anchoring device be marked with the most recent or next inspection date.
e) Remove the
XTIRPA
System from service if a problem or an unsafe or defective condition is found
during the inspection. Return to an authorized service center or the manufacturer for service.
f) Replacement components and parts and additional maintenance and servicing procedures must be
completed by an authorized service center which has been approved by the manufacturer, or by the
manufacturer itself.
g) If the adjustable supporting legs of the expandable coupling system for
XTIRPA
TM
vehicles and
counterbalanced trucks do not move freely, they must be lubricated with a light machine oil.
h) Establish a monthly inspection which should be done by a competent person (person who is familiar,
has been trained and has read and fully understands this instruction and safety manual), other than the
user.
i) Periodically clean the exterior of the system using water and mild detergent. Clean labels as required.
j) When lowering the removable systems, it is important to slowly place the system on the ground, to
avoid damaging components.
k) Store the
XTIRPA
System in a clean and dry environment, out of direct sunlight. Avoid areas with
chemical or toxic vapors, substances or environments. Do not immerse or leave in direct contact with
water, as corrosion and rust may occur. Inspect the
XTIRPA
System after any period of extended
storage and at least once a month.
l) The
XTIRPA
System and its components was designed for 10 years of continuous service. The life
expectancy of the
XTIRPA
System and its components will be determined after periodic and monthly
inspections that will determine whether or not the product may remain in service.
m) All components and parts of the
XTIRPA
System should be stored in separate bags to facilitate
transport and handling.
WARNING:
A periodic inspection should be performed at least once every twelve months.