ENG
32
Installation of indoor unit
open-end
wrench
union nut
pipe
torque wrench
indoor pipe
insulating pipe
4.
Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and
then wrap it with tape.
Hex nut diameter
Tightening torque (N.m)
Ø 6
15~20
Ø 9.52
30~40
Ø 12
45~55
Ø 16
60~65
Ø 19
70~75
Step 6: install drain hose
1.
Connect the drain hose to the
outlet pipe of indoor unit.
2.
Bind the joint with tape.
drain hose
outlet pipe
tape
outlet
pipe
drain hose
drain hose
insulating pipe
Note:
• Add insulating pipe in the indoor drain hose
in order to prevent condensation.
• The plastic expansion particles are not provided.
Step 7: connect wire of indoor unit
1.
Open the panel, remove the screw
on the wiring cover and then take
down the cover.
panel
screw
wiring cover