ENG
12
Introduction for buttons on remote controller
16
SLEEP button
●
Press this button, can select Sleep 1 (
), Sleep 2 (
), Sleep 3 (
) and cancel
the Sleep, circulate between these, after electrified, Sleep Cancel is defaulted.
●
Sleep 1 is Sleep mode 1, in Cool modes: sleep status after run for one hour, the main
unit setting temperature will increase 1°C, 2 hours, setting temperature increased
2°C, the unit will run at this setting temperature; In Heat mode:sleep status after run
for one hour, the setting temperature will decrease 1°C, 2 hours, setting temperature
will decrease 2°C, then the unit will run at this setting temperature.
●
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presettinga
group of sleep temperature curve.
In Cool mode:
(1)
When setting the initial temperature 16°C-23°C, after turned on Sleep function, the
temperature will be increased 1°C in every hour, after 3°C the temperature will be
maintained, after 7hours, the temperature will be decreased 1°C, after that the unit
will keep on running under this temperature;
(2)
When setting the initial temperature 24°C-27°C, after turned on Sleep function, the
temperature will be increased 1°C in every hour, after 2°C the temperature will be
maintained, after 7hours, the temperature will be decreased 1°C, after that the unit
will keep on running under this temperature;
(3)
When setting the initial temperature 28°C-29°C, after turned on Sleep function,the
temperature will be increased 1°C in every hour, after 1°C the temperature will be
maintained, after 7hours, the temperature will be decreased 1°C, after that the unit
will keep on running under this temperature;
(4)
When setting the initial temperature 30°C, under this temperature setting, after
7hours, the temperature will be decreased 1°C, after that the unit will keep on run-
ning under this temperature;
In Heat mode:
(1)
Under the initial presetting temperature 16°C, it will run under this setting tempera-
ture all along.
(2)
Under the initial presetting temperature17°C-20°C, after Sleep function started up,
the temperature will decrease 1°C in every hour, after 1°C decreased, this tempera-
ture will be maintained.
(3)
Under the initial presetting temperature 21°C-27°C, after Sleep function started up,
the temperature will decrease 1°C in every hour, after 2°C decreased, this tempera-
ture will be maintained.
(4)
Under the initial presetting temperature 28°C-30°C, after Sleep function started up,
the temperature will decrease 1°C in every hour, after 3°C decreased, this tempera-
ture will be maintained.