5
WARNING
Attachment
●
Including an circuit break with suitable capacity, please note the following table. Air switch
should be included magnet buckle and heating buckle function, it can protect the circuit-short
and overload.
●
Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.
●
Don’t use unqualified power cord.
●
Make sure the power supply matches with the requirement of air conditioner. Unstable power
supply or incorrect wiring or malfunction. Please install proper power supply cables before using
the air conditioner.
●
Properly connect the live wire, neutral wire and grounding wire of power socket.
●
Be sure to cut off the power supply before proceeding any work related to electricity and safety.
●
Do not put through the power before finishing installation.
●
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similar-
ly qualified persons in order to avoid a hazard.
●
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.
●
The appliance shall be installed in accordance with national wiring regulations.
●
Installation must be performed in accordance with the requirement of NEC and CEC by authorized
personnel only.
●
The air conditioner is the first class electric appliance. It must be properly grounding with spe-
cialized grounding device by a professional. Please make sure it is always grounded effectively,
otherwise it may cause electric shock.
●
The yellow-green wire in air conditioner is grounding wire, which can’t be used for other purposes.
●
The grounding resistance should comply with national electric safety regulations.
●
The appliance must be positioned so that the plug is accessible.
●
All wires of indoor unit and outdoor unit should be connected by a professional.
●
If the length of power connection wire is insufficient, please contact the supplier for a new one.
Avoid extending the wire by yourself.
●
For the air conditioner with plug, the plug should be reachable after finishing installation.
●
For the air conditioner without plug, an circuit break must be installed in the line.
●
If you need to relocate the air conditioner to another place, only the qualified person can perform
the work. Otherwise, it may cause personal injury or damage.
●
Select a location which is out of reach for children and far away from animals or plants.If it is unavoi-
dable, please add the fence for safety purpose.
●
The indoor unit should be installed close to the wall.
●
Instructions for installation and use of this product are provided by the manufacturer.
Working temperature range
Indoor side DB/WB ( °C )
Outdoor side DB/WB ( °C )
Maximum cooling
32/23
52/32
Maximum heating
27/-
24/18
NOTICE:
●
The operating temperature range (outdoor temperature) for cooling only unit is
-18°C ~ 52°C ; for heat pump unit is -30°C ~ 52°C .