background image

5

www.InnovaHeatingCo.com

Read and understand the installation, operating, and maintenance 

instructions thoroughly before installing or servicing this 

equipment. Only trained, qualified personnel with proper electrical 

experience may install or service this equipment. Improper 

installation, adjustment, alteration, service, or maintenance can 

cause property damage, serious injury, or death. 

Damage caused by improper use is not the responsibility of the 

manufacturer. It is important to use this appliance responsibly 

and to follow all the procedures, warnings, and safety instructions 

contained in this manual. Any use not recommended by the 

manufacturer may result in fire, electric shock, or personal injury.

Some parts of this product can become very hot and cause burns. 

Keep bare skin away from hot surfaces to avoid burns. The front, 

sides, and rear of the heater should be at least 3.3ft (1m) away 

from flammable materials such as furniture, pillows, linen, papers, 

clothes, etc.

Placement of explosive objects, flammable objects, liquids, and 

vapors close to the heater may result in explosion, fire, property 

damage, serious injury, or death. Do not store or use explosive 

objects, liquids, or vapors in the vicinity of the heater.

The outside surfaces of the heater are hot during operation and 

after operation. If contact is made, permanent skin damage may 

occur. Do not move, handle, or service the unit during operation 

or while hot.

 

In order to avoid overheating, never under any circumstances 

cover the appliances during operation, as this would lead to 

dangerous overheating.

Failure to comply with the published clearances to combustibles 

could result in personal injury, death, and/or property damage.

Particular attention must be given where children and vulnerable 

people are present. Children should be kept away unless 

continuously supervised.

If the power cable has been damaged, it must be replaced by 

the manufacturer or the technical service center or by a qualified 

person so as to avoid all risks.

Do not attempt to alter the unit in any manner, including painting 

the surface of the unit.

Do not insert any foreign objects to the front cover or front 

opening of the heater as this may cause an electric shock or fire or 

damage the heater.

Do not operate any heater after it malfunctions. Disconnect 

power at service panel and have heater inspected by a reputable 

electrician before reusing.

INSTALLATIONS:

Installations must comply with local building codes; all electrical 

connection must be in compliance with the National Electric 

Code (NEC) and local codes for outdoor wiring. Contact the local 

building inspector and/or fire marshal for guidance.

The packaging needs to be removed before installation, please 

contact supplier if there is any damage or defectiveness on the 

appliance.

Heater and switches should not be installed near bathtubs, wash 

basins, showers, sinks, swimming pools, recreational vehicles, 

boats, and wardrobes.

The appliance must not be located in front of or below a fixed 

socket-outlet.

Before using the appliance check the label on the heater for 

proper voltage, please make sure the requirement of the power 

socket and power supply line correspond to the load specified. 

Check the current capacity of your fuses. HEATER MUST 

CONNECT TO EARTH PROVIDED SOCKET.

Safety warning labels must be maintained on the heater. Contact 

either your local distributor or the product manufacturer for 

obtaining replacement signs or labels.

Never place the power cable on top of the heater or under any 

coverings. Power cord need to be placed away from the traffic 

areas.

The heater can only mount horizontally to prevent from swaying 

and putting stress on the heating elements. Check local codes for 

seismic bracing requirements for outdoor heating equipment.

Air flow must not be restricted. The space above the heater must 

not be enclosed in order to allow air for ventilation.

WARNING

Warnings

The heater should only be used as described in this manual. Any use not recommended 

by the manufacturer may result in fire, electric shock, or personal injury.

CAUTION – High temperature, risk of fire, keep electrical cords, drapery, 

furnishings, and other combustibles at least 3.3 feet (1m) from the front of 

the heater and away from the side and rear.

Each enclosed area within which the heater is located shall have a 

temperature control device.

The heater does not feature a device to control ambient temperature. 

All users should be made aware of all aspects of operation and safety and 

these instructions should be retained for reference.

Содержание EF15

Страница 1: ...REFERENCE READ THIS MANUAL CAREFULLY SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE Version 2022705 FOR MODELS EF15 EF17 EF18 EF19 INSTALLATION INSTRUCTION SERVICE MANUAL ...

Страница 2: ...ons containing placement and orientation guidelines that are extremely important to a safe and efficient installation Please keep this manual in a safe place for future reference and urgent needs Please contact our customer service department or visit our website at https innovaheatingco com for the latest instruction manual Note Innova Heating Co reserves the right to make changes to specificatio...

Страница 3: ...SPECIFICATIONS Page 7 ELECTRICAL INSTALLATIONS Page 8 MOUNTING HEIGHT CLEARANCES Page 9 CEILING MOUNT WALL MOUNT FLUSH MOUNT Page 10 INSTALLING QUARTZ ELEMENT Page 11 MAINTENANCE INSTRUCTIONS Page 12 TECHNICAL SERVICE Page 12 REPLACEMENT PARTS Page 13 GENERAL NOTES Page 13 MANUFACTURER WARRANTY Page 14 Contents ...

Страница 4: ... 1m apart from each other Heater should never be blocked by any other object Heater should not be operated within 25ft 7 6m of any flammable or explosive materials Heater is not to be used if the heating element is damaged or cracked According to local wiring codes disconnection provisions should be incorporated in the appliance When possible install heaters under a protective covering such as a r...

Страница 5: ...eater as this may cause an electric shock or fire or damage the heater Do not operate any heater after it malfunctions Disconnect power at service panel and have heater inspected by a reputable electrician before reusing INSTALLATIONS Installations must comply with local building codes all electrical connection must be in compliance with the National Electric Code NEC and local codes for outdoor w...

Страница 6: ... Overview 1 3 2 1 Standard Grill 2 Heater Body 3 Quartz Element What s in the box Please inspect that all parts are included in the package Instruction Manual x1 Parts Bag Outer Nut x2 Washers x2 Mounting Brackets x2 Element x1 ...

Страница 7: ...andard for Fixed and Location Dedicated Electric Room Heaters UL 2021 and the Canadian Standard for Electric Air Heaters CSA C22 2 No 46 MODEL OUTPUT WATTAGE SUPPLY VOLTAGE SUPPLY AMP DRAW DIMENSIONS WEIGHT EF15120 1500W 120V 12 5 42 x 9 x 9 106 7 x 22 9 x 22 9cm 15 4 lbs 7Kg EF17120 1700W 120V 14 2 42 x 9 x 9 106 7 x 22 9 x 22 9cm 15 4 lbs 7Kg EF18120 1800W 120V 15 0 42 x 9 x 9 106 7 x 22 9 x 22 ...

Страница 8: ... and follow installation requirements outlined in this manual The Appliance MUST be connected to a properly grounded electrical source L1 T1 Ground Terre Line Hot Black Black Neutral white Turn the heater on only when you need heat and avoid any misuse Do not use the heater if the ambient temperature exceeds 80 F 26 6 C Before connecting the appliance make sure that the voltage is the same as indi...

Страница 9: ...ard 8ft 244 cm Canadian Standard 2 The minimum clearances from the ceiling walls and other objects are shown in the pictures below 4 Building materials with low heat tolerance i e plastics vinyl siding canvas tri ply etc may be subject to degradation at lower temperatures It is the installer s responsibility to ensure that adjacent materials are protected from deterioration Once the product is pow...

Страница 10: ...OUR FIRE RATED WHIP Beam Type X 5 8 Drywall Accessible Junction Box Ceiling Whip WALL MOUNT APPLICATION F L U S H M O U N T A P P L I C A T I O N Please reference FLUSH MOUNT KIT MODEL EF39FMPFS EF39FMPFB Instruction Manual for Flush Mount application Make sure heater is levelled during installation to achieve equal heat distribution Improper levelling can cause shorter lifespan of the Quartz Elem...

Страница 11: ... LOCK BRACKET INSERT ELEMENTS INTO SUPPORT BRACKET Loosen screw to open Lock Bracket Tighten screw once closed to secure the Quartz Element Open Lock Bracket to insert Quartz Element x1 1 3 4 5 2 TIGHTEN OUTER HEX NUT LOCK WASHER AND LEAD WIRE RING TERMINAL TO THE THREADED STUD Lead Wire Ring Terminal Lock Washer Outer Hex Nut tightened to the Threaded Stud of the Quartz Element ...

Страница 12: ...r 4 These heating units should be cleaned and inspected every three months 5 Avoid the use of harsh detergents solvents and abrasive or aerosol cleaners as they may damage surfaces 6 When cleaning the heater always inspect the back of the heater for build up of insects bird droppings dust salt build up etc and clean back thoroughly 1 If the heater is removed from mounting brackets it should be sto...

Страница 13: ...reme cold windy environments may be reduced Item Description Volts Watts Length in Fits EF15120E 1500W 120V Quartz Element 120 1500 33 EF15120 EF17120E 1700W 120V Quartz Element 120 1700 33 EF17120 EF18120E 1800W 120V Quartz Element 120 1800 33 EF18120 EF19120E 1900W 120V Quartz Element 120 1900 33 EF19120 Item Description Qty Fits EF39BOD Body Reflector 39 1 EF15120 EF39LWR LEAD WIRE SET 39IN 1 E...

Страница 14: ...very charges Damage or repairs due to faulty installation misapplication negligence thermal shock earthquake flood fire and purposeful damage to the heater Failure to operate due to electrical service issues including voltage conditions blown fuses or circuit breakers Damage due to the inadequacy or interruption of electrical service Normal product wear oxidation scratches heating element replacem...

Страница 15: ...15 www InnovaHeatingCo com ...

Страница 16: ...hone Model Serial No Dealer s Name Date Purchased Dealer s Address This Warranty Registration Card must be returned within 30 days of purchase to properly activate your warranty This information is for our internal use only 33 West Beaver Creek Road Richmond Hill ON L4B 1L8 Canada Tel 1 800 660 5391 www innovaheatingco com ...

Страница 17: ...17 www InnovaHeatingCo com ...

Страница 18: ... InnovaHeatingCo com 1 800 660 5391 T 905 695 2055 F 905 695 2056 33 West Beaver Creek Richmond Hill ON L4B 1L8 33 West Beaver Creek Road Richmond Hill ON L4B 1L8 Canada Postage Here www InnovaHeatingCo com ...

Отзывы: