1

 

GENERALITY 

1.1 

INTRODUCTION

 

This manual has been conceived with the aim of making the installation and management of your system as simple as possible. 
By reading and applying the suggestions in this manual, you will be able to get the best performance from the product you have purchased. 
We would like to thank you for the choice you made with the purchase of our product. 
Read this booklet carefully before carrying out any operation on the unit. 
You must not install the unit or carry out any work on it unless you have carefully read and understood this manual in all its parts. In particular, all 

the precautions listed in the manual must be taken. 
The documentation supplied with the unit must be delivered to the plant manager so that he can keep it carefully (at least 10 years) for any future 

assistance, maintenance and repairs. 
The installation of the unit must take into account both the purely technical requirements for proper functioning, and any local legislation in force 

and specific prescriptions. 
Make sure that upon delivery of the unit, there are no obvious signs of damage caused by transportation. In this case indicate it on the delivery 

note. 
This manual reflects the state of the art at the time the machine was marketed and cannot be considered inadequate as it is subsequently updated 

on the basis of new experiences. The Manufacturer reserves the right to update the production and the manuals, without the obligation to update 

the previous ones, except in exceptional cases. 
Contact the Manufacturer's Sales Department to receive further information or updates to the technical documentation and for any improvement 

proposals to this manual. All reports received will be rigorously examined. 

 

1.2 

BASIC SAFETY RULES  

 

  We remind you that the use of products that use electricity and water implies the observance of some fundamental safety rules: 
 

 

The use of the appliance by disabled and unassisted persons is prohibited. 

 

It is forbidden to touch the appliance with bare feet and with wet or humid peers of the body. 

 

Any cleaning operation is forbidden before disconnecting the appliance from the power supply by setting the main system switch to off. 

 

It is forbidden to modify the safety or adjustment devices without the authorization and indications of the manufacturer of the appliance. 

 

It is forbidden to pull, disconnect or twist the electric cables coming out of the appliance, even if it is disconnected from the mains 

electricity supply. 

 

It is forbidden to introduce objects and substances through the air intake and delivery grilles. 

 

It is forbidden to open the access doors to the internal parts of the appliance without first setting the system main switch to off. 

 

It is forbidden to disperse and leave the packaging material within the reach of children as it can be a potential source of danger. 

 

Respect the safety distances between the machine and other equipment or structures to ensure sufficient access space to the unit for 

maintenance and assistance operations as indicated in this booklet. 

 

The unit must be powered with electrical cables with a section suitable for the power of the unit. The voltage and frequency values must 

correspond to those indicated for the respective machines; all the machines must be earthed as per the regulations in force in the various 

countries. 

 
 

 

 

Содержание DUCTO - SLC

Страница 1: ...ergie com Share capital int vers 150 000 Tax code VAT number 01827470228 REA registration nr 180610 Reg Companies TN 10656 Mechanographic number TN025148 www innovaenergie com Page 1 N420355A_Manuale...

Страница 2: ...TS 8 1 10 DISASSEMBLY AND DISPOSAL 8 1 11 MAIN COMPONENTS UNITS 8 1 12 DIMENSIONAL 9 2 INSTALLATION 10 2 1 INSTALLATION CONDITIONS 10 2 2 UNIT POSITIONING 10 2 3 CONDENSATE DRAIN CONNECTION 11 3 AREAU...

Страница 3: ...6 1 OPERATION VERSION S 25 6 2 OPERATION VERSION I 25 6 3 TURNING THE UNIT ON AND OFF 26 6 4 MODIFICATION OF FANS SPEED AND BOOSTER FUNCTION 26 6 5 AUTO FUNCTION 26 6 6 CHANGE OF SEASON 26 6 7 KEY LOC...

Страница 4: ...Sales Department to receive further information or updates to the technical documentation and for any improvement proposals to this manual All reports received will be rigorously examined 1 2 BASIC SA...

Страница 5: ...s the presence of moving parts and involves a risk of damage to exposed people 1 4 WARNINGS The unit must be installed by qualified and authorized personnel according to the regulations in force in th...

Страница 6: ...th connection is made do not ground the appliance on distribution pipes Momentary surges of high intensity could damage the unit Installations performed outside the warnings of this manual or use outs...

Страница 7: ...sale The removal deterioration and illegibility of the plate placed on the unit involves major problems in identifying the machine in the availability of spare parts and therefore in any future maint...

Страница 8: ...t Check the power supply and grounding of the unit 1 10 DISASSEMBLY AND DISPOSAL Do not disassemble or dispose of the product yourself Disassembly demolition disposal of the product must be carried ou...

Страница 9: ...1190 1477 B mm 550 750 950 1150 1437 C mm 240 240 240 240 240 D mm 695 695 695 695 695 AND mm 570 770 970 1170 1457 F mm 637 637 637 637 637 G mm 90 90 90 90 90 H mm 460 660 860 1060 1317 THE mm 150...

Страница 10: ...n installation site where there is sufficient space around the unit for the connections of the air ducts and to be able to carry out maintenance operations the consistency of the ceiling wall floor wh...

Страница 11: ...e for carrying out maintenance activities the opening of the unit cover front and accessibility to the electrical box and to the hydraulic connections must be guaranteed Do not mount the unit with the...

Страница 12: ...positioning the drain is 18 mm in diameter In vertical positioning the drain is 20 mm in diameter Horizontal installation drain Vertical installation drain 3 AREAULIC CONNECTIONS 3 1 AREAULIC CONNECT...

Страница 13: ...Air intake Aeraulic attacks Air delivery and return dimensions table SLC 400 600 800 1000 1200 TO Delivery Base x Height mm 510 x 150 710 x 150 910 x 150 1110 x 150 1370x150 B Shooting Base x Height m...

Страница 14: ...cular inlets D Return plenum with circular inlets The two circular inlets of the unit are made with abs flanges and are 160 mm female diameter 3 Aeraulic attacks Air delivery and return dimensions tab...

Страница 15: ...e to manage the air intake on the rear or front ceiling mounting lower front wall mounting To change the orientation proceed as in the figure to the side removing the screws from the air intake panel...

Страница 16: ...y do not contain foreign materials such as sand stones rust flakes welding drops slag etc Otherwise wash the hydraulic circuit by bypassing the unit Absolutely avoid pump cavitation and the consequent...

Страница 17: ...ny case be careful not to rotate or twist the pipes coming from inside the unit Rotating the pipes during connection could damage the connections inside the unit and cause water leaks during operation...

Страница 18: ...the maximum load that can be reached The relative data are indicated on the attached wiring diagram and on the unit identification plate IS It is forbidden to enter the unit with electric cables unle...

Страница 19: ...C COMMAND S versions wiring diagram CONNECTIONS BY THE CUSTOMER L N PE Power supply 230 1 50 Check power in the previous tables 10v Reference voltage signal Voltage supplied by the motor I max 20 ma Y...

Страница 20: ...ontact closed Unit on CP Contact presence Contact closed unit off CHILLER Generator pump consent Clean Contact hot cold request activation WATER VALVE N EV1 Water valve post battery Live contact 220v...

Страница 21: ...network and management of the unit through a dedicated APP The controls can be supplied in both White and Black colors The control is connected to the unit via a 0 75 1mm 4 conductor shielded braided...

Страница 22: ...cable with a maximum length of 150 m Carry out a layout in order to minimize the length of the leads terminate the line with the supplied 120 resistor do not make star connections the connection with...

Страница 23: ...3 way valve with dedicated cable and connector The pre wired connector is connected to the terminals on the electronic board N Neutral EV1 Opening command Water valve connection GENERATOR CONNECTION T...

Страница 24: ...unit connection MODBUS RTU CONNECTION TO REMOTE PANEL T H With the connection of the remote panel the machine can be connected to a supervision system directly on the control panel which becomes a sla...

Страница 25: ...olled by the user through the wall mounted touch control EEA649II EEB649II EFA649II EFB649II it is possible to connect humidity regulator and air quality regulator sensors The keys present in the main...

Страница 26: ...p constant As the system pressure drops vary Fan speed management 6 5 AUTO FUNCTION By pressing the auto key the unit will work in automatic mode According to the detected temperature and the set temp...

Страница 27: ...All adjustments are disabled for the user and bL appears when any key is pressed By repeating the sequence the keys are unlocked bL Key lock 6 8 PANEL BRIGHTNESS ADJUSTMENT With the panel off keep th...

Страница 28: ...ted knobs If the conditions of the filters allow it they can be cleaned using a vacuum cleaner or a low pressure compressor WITH AIR INTAKE PLENUM If the air intake plenum accessory is present the fil...

Страница 29: ...nect the condensate drain pipe open the unit cover by releasing the screws on it check and if necessary clean the fans the condensate drain and the walls close the cover and lock the fixing screws For...

Страница 30: ...nger Clean the filters Increase the rotation speed Clean pipes or exchanger Insufficient efficiency of the exchanger Exchanger fins clogged No water flow Clean the surfaces of the exchanger Check the...

Страница 31: ...of an alarm has two display modes an error code present on the EEA649II EEB649II EFA649II EFB649II command a led on the electronic board that shows a flashing sequence with the type of alarm present...

Страница 32: ...n alarm Faulty fan connector or no feedback signal Check the connection of the fan connector to the board Replace the fan control cable 2 flashes off 3 seconds Water probe alarm Broken or missing read...

Страница 33: ..._____________________________________________________________________ __________________________________________________________________________________________________________________________________...

Отзывы: