2.
To record Maximum/Minimum readings, press and release
the
MAX/MIN
button to place the tester in MAX/MIN mode .
The
MAX
icon will be visib le on the displa y. Perform the
desired test; the
maximum
reading achieved during the test
will be recorded and saved in the tester’s memory.
3.
Press the
MAX/MIN
button again. The
MIN
icon will be visi-
ble on the displa y. Perform the desired test; the minimum
reading achieved during the test will be recorded and saved
in the tester’s memory.
•
To scroll between MAX and MIN readings that are stored
in the tester’ s memory, rapidly press and release the
MAX/MIN
button.
4.
To exit MAX/MIN mode press and hold
MAX/MIN
button for
approximately 2-3 seconds, or until MAX/MIN icons disap-
pear from the display.
•
The tester will save the MAX/MIN readings in memory until
the MAX/MIN mode is exited or the tester is turned off.
NOTE:
MAX/MIN functions is not applicab le to the Diode ,
Continuity or Frequency Functions.
BATTERY AND FUSE REPLACEMENT
1.
Turn the Digital A utomotive Tester “
OFF
” and remove the
test leads.
2.
Replace the fuse or batteries as necessary:
•
For battery replacement:
Remove one screw from the battery compartment cover.
Use your finger or a small coin to remo ve the co ver.
Remove the batteries and replace them with two
AA (1-
1/2 Volt alkaline batteries
.
•
For fuse replacement:
Remove the three scre ws (you must remove the meter
stand to remo ve the third scre w) on the bac k of the
meter and separate the case. Remove the fuse from the
fuse holder and replace with a
0.500A/250V - UL Listed
Bussmann, GMA Type (Radio Shack GMA/270
Series: #270-1047)
fuse.
NOTE:
Use a
0.500A/250V, 5x20mm
type fuse ONL Y -
Bussmann, GMA Type (Radio Shack #270-1047 or similar).
Using an incorrect fuse may result in serious injury and/or damage
to the unit.
3.
Reassemble the cover/case and secure with the screws.
18