Troubleshooting guide
If you experience problems with the machine you can consult the troubleshooting guide or
contact us for service at Inkmachines.com
Symptom
Possible cause
Possible Solution
The Motor
does not start
when the power is on but the
Eccenter
can be
turned around (normally) by
hand. ( Electrical fault )
None or to low input
voltage.
Bad cable or power supply.
Bad connection.
Bad connection between the
RCA contact
and the
motor.
Increase voltage (max 13 volts).
Make sure the power supply delivers the
right current. Consult manual if
necessary.
Check clip cord or RCA cable. Replace
if necessary.
Make sure the contact screws are not
loose, tighten the following:
Contact screw motor negative (-)
Contact screw binding post negative
(-)
Contact screw cord positive (+)
.
Loosen the RCA nut
and unscrew
the RCA contact
. Remove possible
oxide by sanding the tip of the contact
that engages with the contact plate of
the motor.
Clean the contact plate
(visible through the threaded hole) with
alcohol on a cotton bud. Turn the RCA
contact until the tip touches the contact
plate gently. Tighten the nut gently also.
Tighten gently
Tighten gently